Model |
TSX3510P |
TSX3510P |
TSX1820 |
TSX1820P |
Voltage range |
0V to 35V |
0V to 18V |
Current range |
0A to 10A |
0A to 20A |
Voltage/Current |
35 volts, 10 amps |
18 volts, 20 amps |
Power |
350 watts |
360 watts |
OUTPUT SPECIFICATIONS |
Operating modes |
Constant voltage or constant current with automatic crossover. |
Overvoltage protection |
10% to 110% of max. output voltage. |
Setting resolution |
10mV, 10mA. |
Load regulation |
<0.01% of max. O/P for 90% change. |
Line regulation |
<0.01% of max. O/P for 10% change. |
Output impedance |
<1mΩ in constant voltage mode.
>5kΩ in constant current mode. |
Ripple & noise |
<1mV RMS typical in constant voltage.
<3mA RMS typical in constant current. |
HF common mode noise |
Typically <3mV RMS, <10mV pk. |
Transient load response |
<20us to within 50mV of set level for 90% load change. |
Temperature coefficient |
typically <100ppm/°C. |
Overvoltage protection delay |
<200us. |
Protection functions |
Overvoltage trip
Regulator overtemperature Sense miswiring. |
Status indication |
Output On lamp
Constant voltage mode lamp
Constant current mode lamp
Trip message on display. |
Output terminals |
4mm output terminals at front, screw terminals for output and sense at rear. |
Output protection |
Full forward and reverse protection via OVP and diode clamp. |
METER SPECIFICATIONS |
Meter types |
Separate 4 digit meters for voltage and current with 12.5mm (0.5") LED displays. |
Meter resolutions |
10mV, 10mA. |
Meter accuracies |
Voltage ±(0.2% + 1 digit)
Current ±(0.5% + 1 digit). |
GENERAL |
Input voltage range |
220V to 240 volts ± 10% or 110 to 120 volts ± 10%, 47 to 63Hz.
Installation Category II. |
Power requirement |
600VA max. |
Electrical safety |
Complies with EN61010-1. |
EMC |
Complies with EN61326. |
Temperature |
+5°C to +40°C operating, 20% to 80% RH, -40°C to +70°C storage. |
Cooling |
Silent fan-less convection cooling. |
Size |
210 x 130 x 350mm (WxHxD)
(half rack width x 3U height). |
Weight |
5.0kg (TSX versions).
5.5kg (TSX-P versions). |
Options |
Rack Mounting kit. |
FRONT PANEL CONTROLS (standard versions) |
Voltage setting |
Via single rotary controls for coarse and fine control. |
Current setting |
Via single turn semi-logarithmic rotary control. |
Overvoltage setting |
Via screwdriver adjustable preset potentiometer. |
Output On/Off |
Latchinh push-push switch operating electronic power control. |
FRONT PANEL CONTROLS (P versions) |
Voltage setting |
Direct keyboard entry or quasi-analogue rotary control. |
Current setting |
Direct keyboard entry or quasi-analogue rotary control. |
Overvoltage setting |
Direct keyboard entry. |
Output On/Off |
Push button control with indicator lamp operating electronic power contro |
Note |
all voltage and current levels set via the keyboard are displayed on a separate 0.3" 4 digit display. This entry preview system ensures that the user can observe the value entered before it is effected thus avoiding possible error. The display is also used for setting additional functions and for displaying watts.
Additional keyboard functions:
Increase or decrease voltage or current in user-selectable steps (delta mode). Store/recall voltage, current & OVP levels from non-volatile memory (25 memories). Set digital interface type(RS232 or GPIB), set baud rate, set address. |
DIGITAL INTERFACES (P versions) |
RS232 |
Variable baud rate, 9600 baud maximum, 9 pin D connector (male). Fully compatible with standard RS232 or TTi addressable RS232 system (ARC). |
IEEE-488 (GPIB) |
Conforming with IEEE488.1 & IEEE488.2. |
Bus Functions |
Set voltage; set current; set OVP; set output On/Off; read output voltage/current. |
Setting resolution |
Voltage - 10mV; Current - 10mA. |
Setting accuracy |
Voltage - ±(0.1% + 10mV);
Current - ±(0.2% + 20mA). |
Response times |
Interface - <15ms (single command);
PSU - Depends on Load conditions, typically 150ms to within 0.1% of final value (except for voltage reduction with low load current which will be longer). |
Readback resolution |
Voltage - 10mV; Current - 10mA. |
Readback accuracy |
Voltage - ±(0.1% + 1 digit);
Current - ±(0.5% +1 digit). |
Operating software |