All waveforms are available up to 10MHz. However,
the purity of triangle and ramp waveforms is not speci-
fied above the frequencies indicated in the Waveforms
section below. |
| Range |
0.1mHz to 10MHz |
| Resolution |
7 digits or 0.1mHZ |
| Accuracy |
<±10ppm for 1 year, 18°C to 28°C |
| Tempco. |
Typically <1ppm/°C outside of 18°C to 28°C |
| Sinewave |
| Distortion |
<0.3% THD to 500kHz, -60dBc to 20kHz, <-50dBc to 1MHz,<-35dBc to 10MHz (typically<-40dBc) |
| Spurii |
Non harmonically related spurii <-65dBc to 1MHz, <(-65dBc +6dB/octave) 1MHz to 10MHz |
| Squarewave |
| Rise & Fall Times |
<22ns |
| Triangle |
| Linearity error |
<0.5% to 30kHz |
| Positive and Negative Ramp |
| Linearity error |
<0.5% to 30kHz |
| Positive and Negative Pulse |
| Multi-Level Squarewave |
Up to 16 steps available per cycle, each step selecta-
ble for amplitude (10 bit resolution) and duration (1 to
1024 samples). Above 27kHz a 36ns edge uncertainty
is introduced. |
| Rise & Fall Times |
<22ns |
| Arbitrary (and Complex) |
A number of “complex” waveforms are pre-
programmed in ROM . A further 5, user defined, wave-
forms may be loaded via the digital interfaces and
stored in non-volatile RAM. |
| Frequency range |
All waveform points can be con-
tinuously output up to 27kHz,
beyond which they are sampled |
| No. of Samples |
1024 10 bit samples |
| Noise |
Wideband white noise with variable amplitude and off-
set. Typical 3dB bandwidth 0.03Hz to 700kHz. |
Symmetry adjustment from 1% to 99% is available for
sinewaves at all frequencies, and for triangles and
ramps at up to 100kHz. Resolution is 0.1%.
For square and pulse waveforms the range is 1% to
99% up to 30kHz and 20% to 80% above 30kHz. |
| Amplitude |
5mV to 20V pk-pk open circuit (2.5mV to 10V into 50/600). |
| Accuracy |
±3% ±1mV at 1kHz into 50Ω/600Ω |
| Flatness |
±0.2dB to 500kHz; ±1dB to 10MHz |
| Pulse Aberrations |
<5% + 2mV |
| DC Offset |
±10V from 50/600. DC offset plus signal peak limited to ±10V. Accuracy ±3% ±10mV |
| Resolution |
3 digits for both amplitude and offset |
| Trigger/Burst |
Phase coherent signal keying - each positive edge of
the Trigger signal will produce one burst of the carrier,
starting and stopping at the phase angle specified by
the Start/Stop phase setting. |
| Carrier frequency |
0.1mHz to 10MHz |
| Carrier waveforms |
All |
| Number of cycles |
1 to 1023 (resolution 1 cycle) or 0.5 to 511.5 (resolution ½ cycle) |
| Trigger rep. rate |
dc to 50kHz internal, dc to 1MHz external |
| Source |
Internal from keyboard or trigger generator. External from EXT TRIG input or remote interface |
| Gated |
Non phase-coherent signal keying - output is On while
Gate signal is high and Off while low. |
| Carrier frequency |
From 0.1mHz to 10MHz |
| Carrier waveforms |
All |
| Trigger rep. rate |
dc to 50kHz internal dc to 1MHz external |
| Gate source |
Internal from keyboard or trigger generator. External from EXT TRIG input or remote interface |
| Sweep |
| Carrier waveforms |
All |
| Sweep Mode |
Linear or logarithmic, single or continuous |
| Sweep Width |
0.1mHz to 10MHz. Phase continuous. Independent setting of the start and stop frequency. |
| Sweep Time |
10ms to 999s (3 digit resolution) |
| Markers |
Two markers variable during sweep. Available at the TRIG/SWEEP OUT socket |
| Sweep Trigger source |
The sweep may be free run or triggered from: keyboard, EXT TRIG input, remote interface |
| Amplitude Modulation |
| Carrier frequency |
0.1mHz to 10MHz |
| Carrier waveforms |
All |
| Depth |
0 to 100% typical, resolution 1% |
| Internal source |
1kHz fixed sinewave or 0.005Hz to 50kHz square wave |
| External |
See “VCA In” section |
| Frequency Shift Keying (FSK) |
Phase coherent switching between two frequencies at
a rate defined by the switching signal source. |
| Carrier frequency |
0.1mHz to 10MHz |
| Carrier waveforms |
All |
| Switch repetition rate |
dc to 50kHz internal, dc to 1MHz external |
| Switching signal source |
Internal from keyboard or trigger generator. External from EXT TRIG input or remote interface |
| Hop |
Up to 16 different “hop” waveforms can be defined in
terms of function, frequency, amplitude, offset and du-
ration. Duration setable per step 1ms to 60s. |
| Start/Stop Phase |
| Carrier frequency |
0.1mHz to 10MHz |
| Carrier waveforms |
All |
| Range |
-360 to +360 degrees |
| Resolution |
1 degree |
| Accuracy |
1 degree up to 30kHz |
| Trigger Generator |
Internal source 0.005Hz to 50kHz squarewave adjust-
able in 20us steps. 3 digit resolution. Available for ex-
ternal use from TRIG/SWEEP OUT socket |
| AUX OUT |
CMOS/TTL levels with symmetry and frequency of
main output and phase of Start-Stop phase setting. |
| TRIG/SWEEP OUT |
Sweep mode, the output is that of the Trigger Gener-
ator at CMOS/TTL levels from 1k.
In Sweep mode the output is a 3-level waveform,
changing from high (+4V) to low (0V) at the start of
sweep, with narrow 1V pulses at each marker point. |
| Ext Trig |
| Frequency Range |
DC to 1MHz |
| Signal Range |
TTL (1.5V) threshold; maximum
input ±10V |
| Min. Pulse Width |
50ns (1ms for Sweep and HOP) |
| VCA In |
| Frequency Range |
DC - 100kHz |
| Signal Range |
2.5V for 100% level change at
maximum output |
| Input Impedance |
Typically 6k |
| Clock In/Out |
TTL/CMOS threshold levels; out-
put impedance typically 50 as
an output |
| Sync Out |
TTL/CMOS logic levels from
typically 50 |
The signals from these sockets are used to phase lock
two or more generators. |
| Full remote control facilities are available through the |
| RS232 |
Variable Baud rate, 9600 Baud maximum. 9-pin D-connector. Fully compatible with ThurlbyThandar ARC (Addressable RS232 Chain) system |
| GPIB (IEEE-488) |
Conforming with IEEE488.1 and IEEE488.2(Optional) |
| Display |
20 character x 4 row alphanumeric LCD |
| Data Entry |
Keyboard selection of mode, waveform etc.; value entry direct by numeric keys or by rotary control. |
| Stored Settings |
Up to 9 complete instrument set-ups may be stored in battery-backed memory. |
| Size |
3U (130mm) height; half-rack (212mm) width, 330mm long |
| Weight |
4.1kg (9lb) |
| Power |
100V, 110-120V or 220-240V ±10% 50/60Hz, adjustable internally. 40VA max. Installation Category II. |
| Operating Range |
+5°C to 40°C, 20-80% RH |
| Environmental |
Indoor use at altitudes up to 2000m, Pollution Degree 2 |
| Safety |
Complies with EN6010-1 |
| EMC |
Complies with EN61326 |
| Options |
GPIB (IEEE-488) interface. 19 inch rack mounting kit. Waveform Manager Plus - (PC-based waveform creation and editing software) |