Particle Channel Sizes |
0.3, 0.5, 0.7, 1.0, 2.0, 5.0 µm |
Size Resolution |
<15% @ 0.5 µm (per ISO 21501-4 requirements) |
Counting Efficiency |
50% at 0.3 µm; 100% for particles >0.45 µm (per ISO 21501-4 and JIS) |
Concentration Limit |
5,950,00 particles/ft3 (210,000,000/m3) @ 10% coincidence loss |
Light Source |
Long life laser diode |
Zero Count |
<1 count per 5 minutes (per ISO 21501-4 and JIS B9921) |
Flow Rate |
0.1 CFM (2.83 L/min) with ±5% accuracy (meets ISO 21501-4 and JIS requirements) |
Flow Rate Control |
Electronic, automatic closed loop (patented flow control technology) |
Calibration |
NIST Traceable with TSI calibration system |
Calibration Frequency |
Recommended minimum once per year |
Sampling Modes |
Manual, automatic, beep; cumulative/differential; count or concentration |
Sampling Time |
1 second to 99 hours |
Sampling Frequency |
1 to 9999 cycles or continuous |
Exhaust |
Internally HEPA filtered |
Communication Mode |
Modbus® TCP over Ethernet or USB |
Alarm Status |
Audible alarm on counts |
Status Indicators |
Low battery, flow, laser |
Environmental Sensors |
Optional Temp/RH probe |
Display |
QVGA 3.5-inch (8.9-cm) touch screen |
Reports |
Provides Pass/Fail on ISO 14644-1, EU GMP, and FS209E reports |
Unit ID |
Configurable IP address |
Security |
2-level password protection to lock out usage and configuration |
Data Storage |
250 Zones
999 Locations
10,000 sample records including: date, time, six total particle size channels, flow status, and instrument status |
Data Transfer |
Via USB storage device, connection to TrakPro™ Lite Secure software through Ethernet or USB cable, or optional TSI FMS software |
Languages |
English, Japanese, German, French, Spanish, and Chinese (simplified), Italian |
Software |
Compatible with TrakPro™ Lite, TrakPro™ Lite Secure and FMS 5 Software |
External Surface |
High Impact injection molded plastic |
Dimension (H x W x D) |
9.4 in. x 4.6 in. x 4.9 in. (23.9 cm x 11.7 cm x 12.4 cm)(without isokinetic inlet, includes handle) |
Weight |
2.2 lb (1.0 kg) with battery |
Power |
110 to 240 VAC, 50 to 60 Hz universal in-line power supply |
Battery |
Removeable/rechargeable Li-Ion |
Battery Life |
>6 hours of continuous use |
Recharge Time |
<2 hours |
Standards |
ISO 21501-4, CE, JIS B9921 |
Warranty |
Two years, extended warranties available |
Operating Range |
41˚to 95˚F (5˚ to 35˚C), 20% to 95% noncondensing |
Storage Range |
32˚ to 122˚F (0˚ to 50˚C), up to 98% RH noncondensing |
Included Accessories |
Operating manual on CD, power supply, battery, isokinetic inlet, purge filter, stylus, USB cable and TrakPro™ Lite Secure |
Optional Accessories |
Spare Battery, external battery charger, isokinetic probe, sample tubing, Temp/RH probe, printer, printer paper and carrying case |