Accurate measurements without the need to precisely position wire or cable in the center of the jaw clamp.SHOP NOW
The SDS3104XHD features an impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding. SHOP NOW
The Megger IMT100 is the most versatile multi-tester for PV systems, electric vehicles and industrial applications.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
0 reviews | Model: TSI ALNOR 8465-06
Air Velocity Transducer, 6" probe
List Price: $1,535.00
Your Price: $1,381.50
Sign-in for EDU Pricing!
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
Answers (1) - Asked by Anonymous
I have this question too (0)
Transducer offers field-selectable velocity range, time constant, output signal, and input power.Probe length of 3 inches (75mm) must be specified at the time an order is placed.
I found this helpful (0)
Inaccurate? (0)
Answered by Anonymous
No. The analog output from the transducer is a continuous linear output in 0-5V, 0-10V, 1-5V, 2-10V, 0-20 mA, or 4-20 mA depending on how it is set by the user. It is field-selectable and changeable.
The warranty period is one year. See the instruction manual for details.
The transducer is returned to TSI for calibration to be performed in a laser-verified wind tunnel. The calibration information is programmed into an EPROM and the typical turnaround is one week for any recalibration or service.
The transducer makes single-point readings. For multi-point readings, additional transducers must be purchased.
Yes, as long as they are connected in parallel for units with voltage output and in series for current output. The resistance of all output indicators in series cannot exceed 270 Ohms on a unit with a current output.
TSI offers the Model 8455 General-Purpose Transducer.
The accuracy for Model 8455 is ±2.0 percent of reading ±0.5 percent of full-scale. The accuracy is the sum of the two components of the specifications.Example: If you have a Model 8455 with a full-scale range of 4,000 ft/min and an output of 0-5 volts and it reads 4.0 V (or 3,200 ft/min) the accuracy is calculated as follows: ±0.5% of reading ±0.5% of full scale = ±0.02(3,200 ft/min) ±0.005(4,000 ft/min) = ±64 ft/min ±20 ft/min, The total accuracy is the then equal to ±84 ft/min or 2.6% at 3,200 ft/min.