| Model |
Z160 |
Z320 |
Z650 |
| Load Regulation |
CV |
0.01% of rated voltage over 0 - 100% load change |
| Line Regulation |
CV |
0.01% of rated voltage over 0 - 100% input change |
| Recovery Time (1) |
CV |
2ms |
| Temperature Coefficient |
CV |
30ppm/°C following 30 minute warm up |
| Temperature Stability |
CV |
0.02% of rated voltage over 8 hours following 30 minute warm up time |
| Warm up Drift (2) |
CV |
<0.05% of rated voltage of rated output voltage |
| Up programming response time (10-90% or 90-10% of Vmax) |
CV |
80ms |
150ms |
150ms |
| Down programming resp time (CV) (10-90% or 90-10% of Vmax) |
Full load |
100ms |
150ms |
150ms |
| Down programming resp time (CV) (90-10% of Vmax) |
Zero load |
2ms |
2.5ms |
3ms |
| Load Regulation |
CC |
0.09% of rated current over 0 - 100% Vout change |
| Load Regulation thermal drift |
CC |
< 0.05% of rated current over 30 minutes after load change |
| Line Regulation |
CC |
0.02% of rated current over a 85 - 132 or 170 - 265VAC line change |
| Temperature Coefficient |
CC |
100ppm/°C of rated current after 30 minute warm up time |
| Temperature Stability |
CC |
0.05% of rated current over 8 hours following 30 minute warm up time |
| Warm up Drift (2) |
CC |
<±0.1% of rated current |
| Vout & Iout programming & readback resolution |
Digitally |
< 0.012% of rated voltage/current |
| Vout & Iout programming & readback accuracy |
Digitally |
0.05% of rated voltage + 0.05% of actual, 0.2% of rated current |
| Voltage & Current Programming |
Analog |
By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k) |
| Voltage & Current Monitoring |
Analog |
0-5V or 0-10V Voltage (user selectable), ±1% accuracy |
| Overvoltage Shutdown (user programmable) |
V |
5 - 176 |
5 - 353 |
5 - 717 |
| Overtemperature Protection |
- |
User selectable - latched or non-latching |
| Display - Voltage |
- |
4 digits. Accuracy 0.5% of rated voltage or current ±1 count |
| Remote On/Off |
- |
By applied voltage or dry contact relay (user selectable logic) |
| Output Good |
- |
Open Collector, Low on fail |
| Model |
Z160 |
Z320 |
Z650 |
| Remote Sense Compensation (per wire) |
V |
5 |
5 |
5 |
| Communication Interface |
- |
RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional |
| Series Operation |
- |
Up to two identical units (with external diodes) |
| Parallel Operation |
- |
Up to six units in master-slave configuration |
| Input Voltage / Frequency (3) |
- |
85-265VAC, 47-63Hz |
| Inrush Current |
- |
< 25A |
| Hold Up Time (Typical) |
ms |
16ms |
| Power Factor Correction |
- |
Complies with EN61000-3-2 Class A (0.99 typ) |
| Operating Temperature |
°C |
0 - 50°C |
| Storage Temperature |
°C |
-20 to +85°C |
| Humidity (non condensing) |
%RH |
Operating: 20 - 90%RH, Storage 10 - 95%RH |
| Cooling |
- |
Internal temperature controlled fan |
| Withstand Voltage |
- |
I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min |
| Insulation Resistance |
- |
>100M at 25°C & 70%RH |
| Vibration (non operating) |
- |
IEC60068-2-64 |
| Shock |
- |
<20G, half sine, 11ms. IEC60068-2-27 |
| Safety Agency Certifications |
- |
UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1) |
| Immunity |
- |
IEC61326 (Designed to meet EN55022 / EN55024) |
| Conducted EMI |
- |
IEC/EN61326-1 Industrial location B, FCC part 15-B, VCCI-B |
| Radiated EMI |
- |
IEC/EN61326-1 Industrial location A, FCC part 15-A, VCCI-A |
| Size (H x W x D) (Excluding handles and busbars) |
mm |
Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm |
| Weight |
kg |
Standard body 1.9kg, Wide body 2.4kg |
| Warranty |
yrs |
Five Years |
Notes:
(1) Recovery to within 0.5% of rated voltage after a load change of 10-90% (Output current 10-100% of Imax)
(2) Over 30 minute warm up time after power on |