Model: UPS1000LI2 Specifications |
Description |
Battery Backup Surge Protector |
SYSTEM SPECIFICATIONS |
Topology |
Line-Interactive, Simulated Sine Wave |
Maximum Power Capacity (Battery & Surge Outlets) |
1000VA / 600W, 8.3A |
Maximum Power Capacity (Surge Only Outlets) |
1800W, 15A |
INPUT |
Number of Phases |
Single (1Φ 2W +G) |
Nominal Voltage |
120VAC |
Acceptable Input voltage |
0 - 150VAC |
Voltage Range |
90 - 140VAC |
Frequency Limits |
60 Hz, +/-6Hz |
Low Voltage Transfer Point |
90V resets to Utility Power at 94V or higher |
High Voltage Transfer Point |
140V resets to Utility Power at 136V or lower |
Input Protection |
Resettable Circuit Breaker |
OUTPUT NON-BATTERY OPERATION |
Voltage Range |
104 - 140VAC |
Voltage Regulation |
120VAC: -13.3% - +16.7% |
Frequency Range |
60Hz: 54 - 66Hz |
Efficiency (Line Mode) |
>96% (Full Load) |
OUTPUT BATTERY OPERATION |
Waveform Type |
Simulated Sine Wave (Step Wave) |
Nominal Voltage |
120VAC |
Voltage Regulation |
Nominal +/-5% (until Low Battery Warning) |
Frequency |
60Hz, +/-0.5Hz (unless synchronized to utility) |
Transfer Time |
6 ms Typical |
Overload Capacity |
AC Mode: 110% for 1-minute then shutdown, 150% Shutdown Immediately
DC Mode: 110% for 20-seconds then shutdown, 150% Shutdown Immediately |
Protection |
Over-Current, Short-Circuit Protected and Latching Shutdown |
REGULATORY COMPLIANCE |
Safety and Approvals |
Conforms to UL Stds 1778 & 1449
Certified to CSA Std C22.2 No. 8 & C22.2 No. 107.3
FCC Class B |
BATTERY SYSTEM |
Battery Type |
Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid |
Typical Recharge Time |
8-hours to 90% capacity from a full load discharge |
Typical Battery Life |
3 to 5 years. Environmental factors do affect battery life. High temperatures, poor utility power, and frequent, short duration discharges have a negative impact on battery life. |
SURGE PROTECTION AND FILTERING |
Voltage Protection Rating (VPR) |
330V Line-Neutral |
Noise Filter |
Normal Mode
Battery : > 30dB 130kHz – 50MHz
Surge Only : > 30dB 120kHz – 50MHz
Common Mode
Battery: > 10dB 300kHz – 50MHz
> 20dB 1.3MHz – 50MHz
Surge Only: > 10dB 280kHz – 50MHz
> 20dB 2.1MHz – 50MHz |
Audible Noise at 1 m (3 ft.) |
<30 dBA |
ENVIRONMENTAL |
Operating Temperature |
0 to 40°C (+32 to +104°F) |
Operating Elevation |
0 to 3000m (0 to +10,000 ft) |
Operating/Storage Humidity |
0 - 95% Non-Condensing |
Storage Temperature |
-15 to +45°C (+5 to +113°F) |
Storage Elevation |
0 to 15,000m (0 to +50,000 ft) |
PHYSICAL |
Size - Net L X W X H |
10.75 x 19 x 3.5" |
Weight - Net |
32 lbs. |
Size - Shipping L X W X H |
21.5 x 6.5 x 6.5" |
Weight - Shipping |
35 lbs |