Model: SXHS20R Specifications |
Voltage Rating |
120 Volts |
Load Rating |
20 Amps at 120 Volts |
Voltage Protection Rating |
330V All Modes |
Input Connector |
NEMA 5-20P |
Output Connector |
(8) NEMA 5-15R |
Attenuation |
Normal Mode: >30dB 80kHz -50MHz
Common Mode: >30dB 70kHz -50MHz |
Power Requirement (no load) |
4 Watts |
Under-Voltage Shutdown |
Adjustable from 80 Volts to 95 Volts, or Disabled. Restores at 105 Volts |
Over-Voltage Shutdown |
Adjustable from 135 Volts to 160 Volts.
Restores at 130 Volts |
Response Time |
100msec Over-Voltage
150msec Under-Voltage |
Under-Voltage Record Event Definition |
AC voltage has dropped below 100V |
Over-Voltage Record Event Definition |
AC voltage has risen above 135V |
Power Outage Event Definition |
AC voltage has dropped below 20V |
Voltmeter Accuracy |
Peak reading type. Typical product accuracy is ±2% between 40V and 180V |
Internal Memory Capacity |
60 Events with timestamp
999 counts of each event type |
Timestamp accuracy |
±2.5% |
Data Interface |
XG-PCS-IK
Custom USB –RJ25 |
Computer Requirements |
For use with Diagnostic Software. Minimum 133MHz Pentium processor (or equivalent), minimum 64MB of RAM, minimum 10MB free hard drive space, VGA or higher resolution monitor, keyboard, mouse, CD or DVD drive, minimum screen resolution of 1024x768, Microsoft Windows 2000/XP/Vista/7 |
Dimensions |
17.44" W x 10.50" D x 1.71" H (1 RU) |
Weight |
12 lbs |
BTU/h |
100 BTU/h Maximum at full rated load |
Temperature Range |
5°C to 40°C |
Humidity Range |
5% to 95% R.H. Non-condensing |
Agency Listings |
ETL Certified to TIA/EIA-568-B.2 Cat 5e
ETL Certified to UL 1449
ETL Certified to UL 1283
ETL Certified to CSA 22.2 No. 8-M1986 (R2008) |
Warranty |
Limited lifetime and limited five years connected protection warranty |