Summit Technology / PowerSight PK3564-PRO+ Complete Power Analysis System
- The Summit Technology PK3564-PRO complete Power Analysis System Includes: PowerSight PS3550 Power Analyzer, Voltage Probes (Qty 4), with jumbo alligator clips, Current Probes (Qty 4), flexible 6000A AC (eFX6000), Wall Charger (CHG1 or CHG4), SD memory card (SD-MEM), Bluetooth Adapter (BTA), USB Cable (USB-COMM), Line-to-DC Operating Converter (LDCm), Weather-Resistant Carrying/Operating Case (CASW), Analysis & Reporting Software (PSM-A), Quick-Start Manual and 2 year Deluxe Warranty (WAR41).
- Great for handheld studies and long-term data logging
- Control from keypad or PC
The Summit Technology PK3564-PRO+ is the ideal package for comprehensive power studies, energy audits, load studies, and more. Wide-range flexible current probes allow you to get into tight and confined spaces, wrap around large conductors, and measure almost any AC circuit that comes your way.
Advanced PowerSight Manager software improves your efficiency and eliminates sources of error at each stage of the monitoring process. CAT IV safety rating and wireless remote control via Bluetooth for even greater safety. SD memory card for redundant storage and essentially unlimited logging capacity.
Connect and Monitor with Safety
Summit Technology recently introduced three PowerSight models: the PS2500 Data Logger, PS3500 Energy Analyzer, and PS4500 Power Quality Analyzer with a stringent CAT-IV safety rating for handheld meters. They can withstand an 8,000 V surge at a 600 V service so you can feelsafe using the meters at 600V circuits or below. With Bluetooth wireless communications you can observe waveforms and real-time
meters, check connections, view phasors, all on a PC or PDA. You can do this remotely and safely from up to 20 feet away from dangerous high voltages without the need to wear cumbersome and restrictive PPE (Personal Protective Equipment)safety gear. Under NFPA 70E it’s mandatory to wear PPE to install the meter’s voltage and current probes on energized circuits. Unfortunately, PPE involves wearing visors that impair visibility of the meter display. Thick gloves also make operation of tiny meter buttons a challenge. Such restrictions can introduce operator errors. With Bluetooth the operator can move to a safe zone a few feet away to remove gloves and visors and operate remotely.
Correct Set-Up
Programming errors can render the survey useless before we have even begun! PowerSight meters allow you to create and save set-up files for different three-phase and single-phase scenarios. Thus you can create a library of set-up files for recall to minimize errors and save time.
Download of Data to a PC
At the end of the study period the user retrieves the meter, wearing the appropriate PPE safety clothing of course, to download data to a PC. Download of data with the PowerSight meters is either via Bluetooth or by a memory card. New models of PowerSight meters have SD memory card slots to accept cards up to 2GB.
Data Analysis and Reports
After downloading, the data is analyzed. Then you generate a report. Summit Technology’s PSM software for the PC has excellent analysis tools for viewing logs and events, zooming and expanding areas of the graphs, and printing of log graphs with annotation. Export of data to an Excel spreadsheet just takes a mouse click! Documenting the results and creating a final report involves reporting on as many as 140 different parameters. Imagine having to manually cut and paste to tabulate each parameter individually, going back and forth between Excel and Word for each value in multiple
Features
- Measure and log all common power measurement types: V, A, W, VA, VAR, kWH, PF, Hz, THD, etc.
- Wide range of operating modes:
- frequency modes for 50Hz, 60Hz, 400Hz, variable frequency systems, and DC to cover all your needs.
- power modes for Positive Power Only (to get the correct answers even if a current probe is backwards), Negative Power Allowed (for regenerative circuits), 2 Current Power (for special distribution and metering systems), quad-power (for multiple parallel single-phase loads)
- Programmed start and/or stop for precise monitoring sessions, Stop When Full, Never Stop
- Able to evaluate all power systems: 3 phase Wye, 3 phase Delta (including 4-wire, open, and grounded), split-phase, single phase, quad single phase (using same source) , 3PT/3CT, 3PT/2CT, 2 current power, DC, quad DC (using same source).
- The included Advanced PowerSight Manager software (PSM-A) improves your efficiency and eliminates sources of error at each stage of the monitoring process:
- TestPlan Manager to organize and automate your tests and the data retrieval
- SureStart expert system to advise if the connections or settings seem correct or not, prior to starting
- Setup Wizard to set your logging parameters according to your application
- ReportWriter to automatically generate error-free reports.
- Benefit from the safety rating of 1000V CAT IIII, 600V CAT IV and Bluetooth Wireless Communications (remote viewing/control of the display without the burden of wearing PPE).
- SD Memory for redundant storage and essentially unlimited logging capacity.
- Extend the measurement range with the use of our industry-widest array of accessories and options:
- measure down to 0.002 amps AC (HA-GFD)
- measure from 5 to 2000 amps DC (DC600/DC2000)
- direct connect and measure to 15kV (5KVP/15KVP)