INPUT |
Voltage
|
4320 |
115/230 VAC ± 10%, user selection |
4520 |
115/230V Auto Range, ± 15% variation |
Frequency |
50/60 Hz ± 5% |
Fuse
|
4320 |
6.3 A 250 V slow blow |
4520 |
15 A slow blow 250 VAC |
DIELECTRIC WITHSTAND TEST MODE |
Output Rating |
4320 |
5 kV @ 20 mAAC
6 kV @ 5 mADC |
|
4520 |
5 kV @ 100 mAAC
6 kV @ 10 mADC |
Voltage Setting/ Display
|
Range:
Resolution:
Accuracy:
|
0 - 5.00 kVAC
0 - 6.00 kVDC
0.01 kV
± (2% of setting + 5 V)
± (2% of reading + 10 V) |
Current Display
|
4320
|
Range: 0 - 20.00 mAAC, 0 - 5.00 mADC
Resolution: 0.01 mA
Accuracy: ± (2% of reading + 0.02 mA) |
4520
|
Range: 0 - 99.99 mAAC, 0 - 10.00 mADC
Resolution: 0.01 mA
Accuracy: ± (2% of reading + 0.06 mA) |
HI-Limit
LO-Limit
|
4320 AC
|
Range: 0 - 20.00 mA
Resolution: 0.01 mA
Accuracy: ± (2% of setting + 0.02 mA) |
4320 DC
|
Range: 0 - 5.00 mA
Resolution: 0.01 mA
Accuracy: ± (2% of setting + 0.02 mA) |
4520 AC
|
Range: 0 - 99.99 mAAC
Resolution: 0.01 mA
Accuracy: ± (2% of reading + 0.06 mA) |
4520 DC
|
Range: 0 - 10.00 mADC
Resolution: 0.01 mA
Accuracy: ± (2% of reading + 0.06 mA) |
Failure Detector |
Audible and Visual |
DC Output Ripple |
4320 |
< 5% Ripple RMS at 6 kVDC @ 5 mA, resistive load |
4520 |
≤ 5% Ripple RMS at 6 KVDC @ 10 mA, resistive load |
Discharge Time |
≤ 200 ms |
Max. Capacitive Load in DC Mode
|
1.00 uF < 1 kV 0.08 uF < 4 kV
0.75 uF < 2 kV 0.04 uF < 5 kV
0.50 uF < 3 kV 0.01 uF < 6 kV |
AC Wave Form |
Sine Wave, Crest Factor = 1.3 - 1.5 |
AC Output Frequency |
Range: |
50/60 Hz, user selection |
Output Regulation |
± (1% of setting + 5 V) from no load to full load |
Dwell Timer
|
Range:
Resolution:
Accuracy: |
0, 0.2 - 999.9 sec, (0 = continuous)
0.1 sec increments
± (0.1% + 0.05 sec) |
Ramp Timer
|
Range:
Resolution:
Accuracy: |
0.1 - 999.9 sec
0.1 sec increments
± (0.1% + 0.05 sec) |
INSULATION RESISTANCE TEST MODE |
Output Voltage
|
Range:
Resolution:
Accuracy: |
100 - 1000 VDC
1 V
± (2% of reading + 5 V) |
Voltage Display
|
Range:
Resolution:
Accuracy: |
0 - 1000 V
1 V
± (2% of reading + 5 V) |
Resistance Display
|
Range: |
1 - 1000 MΩ (4 digit, auto ranging) |
Resolution:
|
|
500 VDC |
1000 VDC |
MΩ |
MΩ |
MΩ |
0.01 |
1.00 - 40.00 |
1.00 - 80.00 |
0.1 |
35.0 - 999.9 |
75.0 - 999.9 |
Hi-Limit |
Range: |
0, 1 - 1000 MΩ (0 = off) |
LO-Limit |
Range: |
0, 0.5 - 999.9 sec, (0 = continuous) |
Delay Timer
|
Resolution:
Accuracy: |
0.1 sec
± (0.1% of 0.05 sec) |
GROUND BOND TEST MODE |
Output Voltage |
Range: |
6 VAC fixed |
Output Frequency |
Range: |
50/60 Hz, user selectable |
Output Current
|
Range:
Resolution:
Accuracy: |
3.0 - 30.0 AAC
0.1 A
± (2% of setting + 0.02 A) |
Current Display
|
Range:
Resolution:
Accuracy: |
0 - 30.0 A
0.1 A
± (3% of reading + 0.01 A) |
HI-Limit
LO-Limit
|
Range: |
0 - 510 mΩ for 3.0 - 10.0 A
0 - 200 mΩ for 10.1 - 25.0 A
0 - 150 mΩ for 25.1 - 30.0 A |
Resolution: |
1 mΩ |
Accuracy: |
± (2% of setting + 2 mΩ) |
Dwell Timer
|
Range:
Resolution:
Accuracy: |
0, 0.5 - 999.9 sec, (0 = continuous)
0.1 sec
± (0.1% + 0.05 sec) |
Milliohm Offset
|
Max. Offset Capability:
Resolution:
Accuracy: |
0 - 100 mΩ
1 mΩ
± (2% of setting + 2 mΩ) |
GENERAL SPECIFICATIONS |
Memories |
Allows storage of up to 6 different test programs and 6 steps per memory and a single step mode |
Remote I/O
|
Input:
Output: |
Test, Reset, Interlock & recall memory 1-6
Pass, Fail, Test-In-Process |
Interface |
Optional RS-232 interface |
Security |
Lockout capability to avoid unauthorized access to test set-up programs |
Calibration |
Software & adjustments made through front panel |
Mechanical |
Bench or rack mount with tilt up front feet |
Dimensions
(W x H x D) |
4320 |
11" x 3.5" x 17" (280 x 89 x 430 mm) |
4520 |
16.9" x 5.2" x 15.7" (430 x 133 x 400 mm) |
Weight
|
4320 |
33 lbs. (15 kg) |
4520 |
54 lbs. (24.5 kg) |