General Specifications |
Housing |
ABS/PC/ TPE |
Protection class |
IP65 |
Dimensions |
306 x 108 x 71 mm (12.4” x 4.3” x 2.8”) |
Weight |
860 g (30.3 oz.) |
Keypad |
sealed, snap action |
Display |
TFT colour, 240 x320 pixels, 3.5 inch, adjustable backlight |
Main processor |
400 MHz ARM® |
Memory |
256 MB RAM, 512 MB Flash |
SD memory card |
1GB |
Operating system |
Microsoft Windows® CE |
DSP processor |
375 MHz floating point |
Dynamic range |
up to 120 dB, 24bit A/D converter |
Communication |
USB 2.0 |
Input channels |
1 x VIB, 1 x SPM, 1 x rpm, 1 x temperature |
Input/output, headset |
3.5 mm stereo plug |
Input/output, communication |
Mini USB |
Power supply |
rechargeable Lithium-Ion
battery pack 5200 mAh or
power adapter |
Battery power |
for min. 18 hours normal use (at 20°C) |
Charge time |
< 4 hours |
Operating temperature |
-20 to 55 °C (-4 to 122 °F) non condensing |
Charging temperature |
0 to 45 °C (32 to 113 °F) |
General features |
language selection, customized
view, voice recording, battery status idication,
transducer line test, metric or imperial units |
Meas. point identification |
NFC transponder for communication with
CondIDTM tags, read distance max. 50 mm (2 inch) |
SPM input |
Shock pulse channels |
1 |
Measuring techniqes |
SPM HD, dBm/dBc, LR/HR and LR/HR HD |
Transducer line test |
TLQ test |
Transducer types |
SPM 40000, 42000, 44000,
probe transducer and quick connector transducer |
VIB input |
Vibration channels |
1 |
Frequency range |
0 (DC) to 20 kHz |
Resolution |
max. 12 800 lines |
Transducer line test |
bias voltage check |
Transducer types |
SPM SLD or IEPE* (ICP) type
with voltage output < 24 Vpp, or
DuoTech accelerometer. Transducer supply of 2.5 mA can be set On/Off |
User defined transd. |
e.g. current clamp, pressure and
flow sensors with voltage output |
Measuring techniqes |
ISO 2372, ISO 10816, FFT with
symptoms, EVAM vibration analysis, HD Enveloping, balancing |
RPM input |
Channels |
1, RPM or temperature |
Measuring range |
1 to 150 000 pulses/min. |
Resolution |
1 pulse |
Accuracy |
± (1 pulse + 0.1% of reading) |
Transducer type |
SPM TTP10, TTL-pulses,
Key phasor®, proximity switch |
NPN/PNP |
Output |
TTL signal for controlling
stroboscope and 12 VDC supply |
Temperature measurement |
Temp. range (TTP10) |
-20 to 300 °C (-4 to 572 °F) |
Accuracy (TTP10) |
± 2.5 °C |
Transducer type |
SPM TTP10 |
Stethoscope |
Settings |
Filter, volume and gain |
Transducer types |
Shock pulse and vibration transducers |