| General Specification |
| Country of Origin |
USA |
| Vibration pickup |
Internal |
Integrated piezoelectric acceleration |
| External |
Accepts a standard 100 mV/g constant current accelerometer |
| Temperature sensor |
Internal infrared temperature sensor |
| Vibration pickup |
Velocity |
Range |
0,7 to 65,0 mm/s (RMS), 0.04 to 3.60 in/s (equivalent Peak), meets ISO 10816 |
| Frequency |
10 to 1 000 Hz, meets ISO 2954 |
| Enveloped acceleration |
Range |
0,2 to 50,0 gE |
| Frequency |
Similar to Band 3 (500 to 10 000 Hz) |
| Temperature |
Range |
20 to +200 °C (–4 to +392 °F) |
| Infrared temperature accuracy |
±2 °C (±3.6 °F) |
| Distance |
Short range, maximum 10 cm (4 in.) from target |
| Operating temperature range |
In use |
–10 to +60 °C (14 to 140 °F) |
| While charging |
0 to 40 °C (32 to 104 °F) |
| Storage temperature |
Less than one month |
–20 to +45 °C (–4 to +113 °F) |
| More than one month, but less than six months |
–20 to +35 °C (–4 to +95 °F) |
| Humidity |
95% relative humidity, non-condensing |
| Enclosure |
IP 54 |
| Approvals |
CE |
| Drop test |
2m (6.6 ft.) |
| Weight |
125g (4.4 oz.) |
| Dimensions |
Length |
200,0 mm (7.90 in.) |
| Width |
47,0 mm (1.85 in.) |
| Height |
25,4 mm (1.00 in.) |
| Battery life |
10 hours before charging again (˜1 000 measurements) |
| With external sensor |
Up to 55% less battery life |
| Supported external sensor |
Any standard accelerometer with 100 mV/g sensitivity constant current |
| External sensor power |
24 V DC at 3,5 mA |
| Charger specifications |
Universal AC/DC wall plug-in |
| 3 to 4 hours for a full charge |
| Input |
90 to 264 V AC, 47 to 60 Hz |
| Output |
5 V DC regulated |