Electrical |
Usable range |
2.3 mm (0.25 to 2.5 mm); 90 mils (10 to 100 mils) |
Sensitivity |
7.87 mV/μm (200 mV/mil) |
Linearity |
±25.4 μm (1 mil) of best straight line over 2.3 mm (90 mil) range |
Frequency range |
DC to 10 kHz (600 000 CPM), down maximum of 3 dB at 10 kHz |
Driver signal output Impedance |
Minimum calibrated load resistance of 3 kΩ; output is protected against miswiring |
Driver signal output Voltage |
Nominal 7.87 mV/μm (200 mV/mil) corresponding to |
Driver signal output |
18 V DC at 2.3mm (90 mils) with –24 V DC supply |
Power supply requirements |
15 mA from –24 to –30 V DC |
Environmental and mechanical |
Operating temperature range |
0 to 65 °C (30 to 150 °F) |
Connections (Power, Signal, GND) |
Five terminal removable and reversible compression terminal block accepting up to 2 mm2 (14 AWG) wire, Three connections necessary per block (–24 V DC, GND, Signal), The CMSS 668P has a permanent fixed connector with the same connection characteristics |
Mounting |
C-DIN rail mount that bolts onto the driver enclosure or the standard four 4.8 mm (0.19 in. or #10) clearance holes in a square on 63.5 mm (2.5 in.) centers |
System performance |
Extended temperatures |
1 m (3.3 ft.) probe and 4 m (13.1 ft.) extension cable operating in a range of –35 to +120 °C (–30 to +250 °F), and driver in the range of 0 to 65 °C (30 to 150 °F) |
Sensitivity |
±10% of 7.87 mV/μm (200 mV/mil) |
Linearity |
±25.4 μm (1 mil) of best straight line over 2.3 mm (90 mil) range |
Minimum target size Flat surface |
16 mm (0.63 in.) |
Minimum target size Shaft diameter |
24 mm (0.93 in.) |