Technical Specification |
Input |
100 mV/g accelerometer |
System |
Metric (mm/s RMS) |
Detection type |
RMS |
Filter |
10 Hz to 1.0 kHz (-3 dB) |
Range 1 |
12.5 |
Range 2 factory preset |
25.0 |
Range 3 |
37.5 |
Range 4 |
50.0 |
Range 5 |
62.5 |
Power Requirements |
Supply voltage |
+24 V DC (23 V to 28 V). Reverse polarity and transient protection included. |
Supply current |
55 mA |
Total power |
3.1 W maximum |
External fuse |
F250 mA/250 V |
Relay ratings Switching voltage |
30 V DC maximum or 125 V AC |
Relay ratings Switching current |
5 A maximum |
Input |
Sensor |
Accelerometer, velocity transducer or electromechanical pickup |
Sensor sensitivity |
100 mV/g, 100 mV/in/sec, 500 mV/in/sec; or specified. |
Sensor approvals |
For CE approved systems, the sensor must be CE approved. |
Sensor OK detection |
Continuously monitors the transmitter bias and signal voltage. If this voltage exceeds preset limits, the 4-20 mA output current is reduced to less than 2 mA (typically 0 mA). |
Output |
Buffered acceleration output |
BNC connector, screw terminal |
Sensitivity |
Depending on used sensor input sensitivity, ± 10% |
4-20 mA DC output |
4-20 mA proportional to the full-scale range. |
Accuracy |
± 5% of full-scale range with single pole filter -3 dB points at specified frequencies for ISO and ISO-LF filters. |
Environmental |
Operating temperature |
-20 °C to +80 °C (-4 °F to +176 °F) |
Storage temperature |
-55 °C to +125 °C (-67 °F to +257 °F) |
Relative humidity |
0-95% relative humidity noncondensing |
Mechanical |
Weight |
6.0 ounces (170 grams) |
Enclosure |
Thermoplastic ABS |
Color |
Black, with gray front panel |
Connectors |
12-pole screw terminal, 2 BNC’s and two 6-pole pluggable connectors. |
Mounting |
32 mm (G style) or 35 mm (T style) DIN-Rail |
Dimensions |
Length |
79 mm (3.11 inches) |
Base |
46 mm (1.80 inches) |
Height |
100 mm (3.95 inches) |