| Power requirements |
| Supply Voltage |
+24 V DC (22 to +28 V DC) |
| Supply current |
250 mA, maximum |
| Power |
6 W, maximum |
| Sensor input |
- Vibration: Constant current source accelerometer (10, 30, 100, 230 mV/g)
- Optional temperature: (10 mV/°C) |
| Vibration process analysis |
| Acceleration Enveloping, gE (Filter band) |
500 Hz to 10 kHz |
| Acceleration, g |
3 Hz to 10 kHz (RMS and Peak Hold) |
| Velocity, mm/s (inch/s), ISO |
10 Hz to 1 kHz or 2 Hz to 1 kHz |
| Vibration signal decay |
1 or 10 seconds (Acceleration Enveloping only) |
| Output |
| Processed vibration |
4 to 20 mA/0 to 10 V DC proportional to full scale vibration |
| Temperature |
4 to 20 mA/0 to 10 V DC proportional to 0 to +120 °C |
| Buffered acceleration output |
BNC connector, screw terminals |
| Output averaging |
On/Off |
| CAN-bus |
SKF protocol (see SKF CMPT CTU Instruction Manual for details) |
| Auxiliary power |
24 V DC/20 mA maximum |
| Environmental |
| Operating temperature |
0 to +70 °C (32 to +160 °F) |
| Storage temperature |
-40 to +85 °C (-40 to +185 °F) |
| Humidity |
95% maximum |
| IP rating |
IP20 |
| Mechanical |
| Weight |
0,225 kg (0.102 lbs.) |
| Enclosure |
Thermoplastic ABS |
| Color |
Gray |
| Connectors |
Two 8-pole pluggable screw clamp type (16 total) |
| Wiring |
0,2 to 2,5 mm (24 to 12 AWG) |
| Mounting |
35 mm DIN-rail type EN50022 with steel retaining clip |
| Minimum space between CTU’s |
5 mm |
| Dimensions |
- Height: 75 mm (2.95 in.)
- Width: 45 mm (1.77 in.)
- Depth: 118 mm (4.65 in.) |
| Approval |
CE |