Power requirements |
Supply Voltage |
+24 V DC (22 to +28 V DC) |
Supply current |
250 mA, maximum |
Power |
6 W, maximum |
Sensor input |
- Vibration: Constant current source accelerometer (10, 30, 100, 230 mV/g)
- Optional temperature: (10 mV/°C) |
Vibration process analysis |
Acceleration Enveloping, gE (Filter band) |
500 Hz to 10 kHz |
Acceleration, g |
3 Hz to 10 kHz (RMS and Peak Hold) |
Velocity, mm/s (inch/s), ISO |
10 Hz to 1 kHz or 2 Hz to 1 kHz |
Vibration signal decay |
1 or 10 seconds (Acceleration Enveloping only) |
Output |
Processed vibration |
4 to 20 mA/0 to 10 V DC proportional to full scale vibration |
Temperature |
4 to 20 mA/0 to 10 V DC proportional to 0 to +120 °C |
Buffered acceleration output |
BNC connector, screw terminals |
Output averaging |
On/Off |
CAN-bus |
SKF protocol (see SKF CMPT CTU Instruction Manual for details) |
Auxiliary power |
24 V DC/20 mA maximum |
Environmental |
Operating temperature |
0 to +70 °C (32 to +160 °F) |
Storage temperature |
-40 to +85 °C (-40 to +185 °F) |
Humidity |
95% maximum |
IP rating |
IP20 |
Mechanical |
Weight |
0,225 kg (0.102 lbs.) |
Enclosure |
Thermoplastic ABS |
Color |
Gray |
Connectors |
Two 8-pole pluggable screw clamp type (16 total) |
Wiring |
0,2 to 2,5 mm (24 to 12 AWG) |
Mounting |
35 mm DIN-rail type EN50022 with steel retaining clip |
Minimum space between CTU’s |
5 mm |
Dimensions |
- Height: 75 mm (2.95 in.)
- Width: 45 mm (1.77 in.)
- Depth: 118 mm (4.65 in.) |
Approval |
CE |