| Rohde and Schwarz ZN-Z84 Specifications |
| GENERAL FEATURES |
| Frequency Range |
|
10 MHz to 8.5 GHz |
| Impedance |
|
50 Ω |
| VNA Port Connector Type |
|
SMA, female |
| Number of VNA Ports |
R&S®ZN-Z84 all models |
2 to 4 |
| Test Port Connector Type |
|
SMA, female |
| Number of Test Ports |
R&S®ZN-Z84 base unit |
6 to 24 |
| Switching Configuration |
Base unit, B22, B32, B42 |
full crossbar |
| Switching Configuration |
Base unit, B24, B34, B44 |
VNA ports A, C to test ports 1 to 6,
13 to 18, full crossbar
VNA ports B, D to test ports 7 to 12,
19 to 24, full crossbar |
| Damage Level |
|
+23 dBm |
| Damage DC Voltage |
|
12 V |
| 0.1 dB Compression |
at 2 GHz |
20 dBm |
| PERFORMANCE DATA |
| |
|
10 MHz to 50 MHz (in dB) |
50 MHz to 2 GHz (in dB) |
2 GHz to 4 GHz (in dB) |
4 GHz to 6 GHz (in dB) |
6 GHz to 8.5 GHz (in dB) |
| Insertion Loss |
R&S®ZN-Z84 B22, B32, B42, B34, B44 |
| any VNA port to any test port |
< 6 |
< 5 |
< 6.5 |
< 8 |
< 9 |
| Insertion Loss |
R&S®ZN-Z84 B22 (B32, B42) |
| VNA port A, B to test ports 1 to 3, 7 to 9 |
< 6 |
< 5 |
< 6.5 |
< 8 |
< 9 |
| VNA port A, B to test ports 4 to 6, 10 to 12 |
< 6 |
< 6 |
< 8.5 |
< 10 |
< 12 |
| VNA port C, D to test ports 1 to 3, 7 to 9 |
< 6 |
< 6 |
< 8.5 |
< 10 |
< 12 |
| VNA port C, D to test ports 4 to 6, 10 to 12 |
< 6 |
< 5 |
< 6.5 |
< 8 |
< 9 |
| Insertion Loss |
R&S®ZN-Z84 base unit, B24 |
| VNA port A, B to test ports 1 to 3, 7 to 9 |
< 6 |
< 3 |
< 4.5 |
< 5.5 |
< 6 |
| VNA port A, B to test ports 4 to 6, 10 to 12 |
< 6 |
< 5 |
< 6.5 |
< 8 |
< 9 |
| VNA port C, D to test ports 1 to 3, 7 to 9 |
< 6 |
< 5 |
< 6.5 |
< 8 |
< 9 |
| VNA port C, D to test ports 4 to 6, 10 to 12 |
< 6 |
< 3 |
< 4.5 |
< 5.5 |
< 6 |
| Raw Load Port Match |
Any selected test port (active) |
> 8, 15 (typ.) |
> 12, 20 (typ.) |
> 10, 15 (typ.) |
> 10, 15 (typ.) |
> 10, 15 (typ.) |
| Any unselected test port (passive) |
> 15, 20 (typ.) |
> 20, 25 (typ.) |
> 20, 23 (typ.) |
> 20, 23 (typ.) |
> 15, 20 (typ.) |
| Isolation |
Any unselected test port to any VNA port |
> 90 |
> 90 |
> 85 |
> 75 |
> 70 |
| Remote Control |
| USB |
Universal serial bus connector (type B) |
| LAN |
Local area network connector 10/100BASE-T, RJ-45 |
| Direct Connect |
Direct connection to internal VNA measurement bus (R&S®ZNB/T option -B12 needed) |
| Switching Times |
| USB |
With software handshake turned on |
< 1 ms (nom.) |
| LAN |
With software handshake turned on |
< 2 ms (nom.) |
| Direct Control |
|
< 100 µs (nom.) |
| GENERAL DATA |
| Temperature Loading |
Operating temperature range |
+18 °C to +28 °C |
| Permissible temperature range |
0 °C to +50 °C |
| Storage temperature range |
-40 °C to +60 °C |
| |
In line with IEC 60068-2-1 and IEC 60068-2-2 |
| Damp Heat |
|
+40 °C at 85 % rel. humidity,
in line with IEC 60068-2-30 |
| Mechanical Resistance |
Vibration, sinusoidal |
5 Hz to 150 Hz, in line with IEC 60068-2-6 |
| Vibration, random |
10 Hz to 300 Hz, in line with IEC 60068-2-64 |
| Shock |
40 g shock spectrum,
in line with IEC 60068-2-27, MIL-STD 810 |
| Calibration Interval |
|
1 year |
| EMC, RF emission |
|
In line with CISPR 11/EN 55011 group 1
Class B (for a shielded test setup) |
| EMC, other emissions and immunity |
|
In line with IEC/EN 61326 |
| Emission |
Class B |
| Immunity |
Industrial environment (excluding operating frequency) |
| Safety |
|
In line with IEC 61010-1 and EN61010-1
C22.2 No. 61010-1 and UL61010-1 |
| Power Supply |
|
100 V to 240 V (AC) ±10 %,
50 Hz to 60 Hz/400 Hz ±5 %,
safety class I to VDE 411 |
| Power Consumption |
|
≤ 130 VA |
| Certification Mark |
|
VDE, cCSAus, CE conformity mark |
| Dimensions |
W x H x D |
445 mm x 88 mm x 300 mm (17.52 in x 3.46 in x 11.81 in) |
| Weight |
Depends on options |
5 kg to 7 kg (11 lb to 15.4 lb) |