Designed as an everyday problem solving tool, the Rohde & Schwarz RTM3000 combines the power of ten (10-bit ADC, 10 times the memory and 10.1" touchscreen) with a Rohde & Schwarz probe interface for use with all Rohde & Schwarz probes.
The display, which is the largest capacitive display (10.1") with the highest resolution (1280 x 800 pixel) in its class, works just like your smartphone. Simply touch the screen to quickly navigate in pop-up menus and use gesturing to easily scale, zoom and move a waveform.
The 10-bit A/D converter yields up to a fourfold improvement over conventional 8-bit A/D converters. You get sharper waveforms with more signal details.
40 Msample memory depth is available on each channel if all channels are active. When interleaved, 80 Msample are available to capture longer signal sequences for more analysis results.
With the Rohde & Schwarz probe interface, all Rohde & Schwarz probing solutions can be used - for perfect connections to any DUT.
The R&S RTM3000 is more than just an oscilloscope. It offers a logic analyzer, protocol analyzer, waveform and pattern generator, digital voltmeter and dedicated operating modes for frequency analysis, mask tests and long data acquisitions. You can quickly and efficiently debug all kinds of electronic systems - and the R&S RTM3000 satisfies the all-important rule of investment protection at a very attractive price.
See small signal details in the presence of large signals
10-bit vertical resolution - 1024 levels, 4 times more than 8-bit ADC
The R&S RTM3000 features a customized Rohde & Schwarz designed 10-bit A/D converter that delivers a fourfold improvement over conventional 8-bit A/D converters.
The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition. For precise measurements of small voltage components, a high resolution of more than 8-bit is essential.
500 μV/div: full measurement bandwidth and low noise
The R&S RTM3000 oscilloscope offers outstanding sensitivity down to 500 μV/div. Traditional oscilloscopes can only reach this level of input sensitivity by employing software-based magnification or by limiting the bandwidth. The R&S RTM3000 oscilloscope shows the signal's real sampling points over the full measurement bandwidth - even at 500 μV/div. This ensures high measurement accuracy.
The accuracy of the signal displayed on the screen depends on the oscilloscope's inherent noise. The R&S RTM3000 oscilloscope precisely measures even at the smallest vertical resolution by using low-noise front ends and state-of-the-art A/D converters.
Capture more at full bandwidth
40 Msample standard and 80 Msample interleaved
The R&S RTM3000 offers a class-leading memory depth: 40 Msample per channel, and even 80 Msample in interleaved mode. This is eight times more than similar oscilloscopes in the same instrument class. It captures longer acquisition sequences even at high sampling rates for more analysis results, e.g. when analyzing transients of switched-mode power supplies.
Segmented memory: 400 Msample with history function
The R&S RTM-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. For example, protocol-based signals with communications gaps, such as I
2C and SPI, can be captured over several seconds or minutes. Thanks to the variable segment
size from 10 ksample to 80 Msample, the 400 Msample memory is optimally utilized; more than 26000 cohesive individual recordings are possible.
In history mode, previous acquisitions to the maximum segmented memory depth of 400 Msample are available for further analysis. Functions such as mask tests, QuickMeas and FFT can be used for further analysis.
Maintains fast sampling rates at all times
Signal faults and important events are detected better with an oscilloscope that offers a high sampling rate. Many applications require long acquisition cycles, for instance when analyzing serial protocols. With a sampling rate of up to 5 Gsample/s and a memory depth of up to 80 Msample, the R&S RTM3000 oscilloscopes really excel here. They accurately display signals over long sequences - right down to the details.
X-in-1 Oscilloscope
The Rohde & Schwarz is an X-in-1 oscilloscope, capable of many different tasks. Powerful software enables users to quickly and efficiently debug all kinds of electronic systems. Please note, some software packages are optional items.
|
Oscilloscope
With a sampling rate of up to 5 Gsample/s and a memory depth of up to 80 Msample, the R&S RTM3000 oscilloscope excels in its class. A waveform update rate of more than 64000 waveforms/s ensures a responsive instrument that reliably catches signal faults. Included tools provide quick results, e.g. QuickMeas, mask tests, FFT, math, cursors and automatic measurements (including statistics). |
|
Logic analyzer
The R&S RTM-B1 option turns every R&S RTM3000 into an intuitive to use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design - synchronously and time-correlated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements. |
|
Protocol analyzer
Protocols such as I2C, SPI and CAN/LIN frequently transfer control messages between integrated circuits. The R&S RTM3000 has versatile options for protocol-specific triggering and decoding of serial interfaces. Selective acquisition and analysis of relevant events and data is possible. With the hardware-based implementation, smooth operation and a high update rate are ensured even for long acquisitions. This is advantageous, for example, for capturing multiple packetized serial bus signals. |
|
Waveform and pattern generator
The integrated R&S RTM-B6 waveform and pattern generator (up to 50 Mbit/s) is useful for educational purposes and for implementing prototype hardware. In addition to common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. You can preview signals before playing them back to quickly check signal correctness. Predefined patterns for e.g. I2 C, SPI, UART and CAN/LIN are provided. |
|
Digital voltmeter
For simultaneous measurements, the R&S RTM3000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel. Measurement functions include DC, AC + DC (RMS) and AC (RMS). |
|
Frequency analysis mode
Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S RTM3000 is activated at the push of a button and by simply entering center frequency and span. Thanks to the R&S RTB2000 oscilloscopes' high performance FFT functionality, signals can be analyzed with up to 128k points. Other tools include cursor measurements and autoset in the frequency domain. |
|
Mask test mode
Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluation. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S RTM3000. This pulse output can be used to trigger actions in the measurement setup. |
|
History and segmented memory mode
The R&S RTM-K15 history and segmented memory option increases the memory from 40 Msample to 400 Msample. You can scroll through past acquisitions and analyze the data using the oscilloscope tools, e.g. protocol decode and logic channels. Serial protocol and pulse sequences are recorded practically without interruptions. |