SENT triggering and decoding |
Protocol configuration |
signal polarity |
idle low, idle high |
clock period (clock tick) |
1 µs to 100 µs |
clock tolerance |
0 % to 25 % |
data nibbles |
1 to 6 |
serial message type |
none, short serial message and enhanced serial message |
CRC version |
legacy (Feb 2008) and v2010, v2016 (latest) |
CRC calculation |
SAE J2716 standard and TLE 4998X |
pause pulse |
no, yes, for constant frame length |
frame length in clock ticks (applicable only when pause pulse = constant frame length) |
104 to 922 |
auto threshold setup |
assisted threshold configuration for SENT triggering and decoding (software) |
Trigger |
source |
any input channel or logical channel |
trigger event setup |
calibration or sync, transmission sequence status, transmission sequence status + data, serial message identifier, serial message identifier + data, error condition (any combination of calibration pulse error, pulse period error, transmission sequence CRC error, serial message CRC error and irregular frame length error) |
transmission sequence status nibble setup |
from 0 to F, condition =, ≠ |
transmission sequence data nibbles setup |
each nibble value from 0 to F, condition =, ≠ |
serial message identifier setup |
from 00 to FF, condition =, ≠; identifier selectable from label list |
serial message identifier type setup (applicable only when the serial protocol = enhanced serial message in protocol configuration) |
4 bit and 8 bit |
serial message data setup |
00 to FF (short serial message) |
000 to FFF (enhanced serial message with 8 bit ID) |
0000 to FFFF (enhanced serial message with 4 bit ID) |
Decode |
source |
any input channel, logical channel |
display type |
decoded bus, tabulated list |
color coding |
transmission sequence: sync/calibration, status, data bits, CRC, pause pulse, calibration pulse error, pulse period error, irregular frame length error and CRC error; serial message: identifier, data, CRC, CRC error |
data format |
hex, decimal, octal, binary, ASCII, symbolic |