Rohde & Schwarz NGA142 Specifications |
Electrical specifications |
Outputs |
The channel outputs are galvanically isolated and not connected to ground. |
Number of output channels |
R&S NGA102, R&S NGA142 |
2 |
Maximum total output power |
R&S NGA102, R&S NGA142 |
80 W |
Maximum output power per channel |
|
40 W |
Output voltage per channel |
R&S NGA101, R&S NGA102 |
0 V to 35 V |
Maximum output current per channel |
R&S NGA101, R&S NGA102 |
6 A |
Voltage ripple and noise |
20 Hz to 20 MHz |
|
R&S NGA101, R&S NGA102 |
< 0.5 mV (RMS), < 10 mV (peak-to-peak) (meas.) |
Current ripple and noise |
20 Hz to 20 MHz |
< 500 µA (RMS) (meas.) |
Load regulation |
load change: 10 % to 90 % |
Voltage |
±(% of output + offset) |
R&S NGA101, R&S NGA102 |
< 0.01 % + 5 mV |
Current |
±(% of output + offset) |
< 0.01 % + 5 mA |
Load recovery time |
10 % to 90 % load change to within 0.2 % of rated voltage |
R&S NGA101, R&S NGA102 |
< 100 µs (meas.) |
Rise time |
10 % to 90 % of rated output voltage, resistive load |
R&S NGA101, R&S NGA102 |
< 50 ms |
Fall time |
90 % to 10 % of rated output voltage, resistive load |
full load: < 10 ms,
no load: < 50 ms |
Programming resolution |
Voltage |
|
1 mV |
Current |
|
1 mA |
Output measurements |
Measurement functions |
|
voltage, current, power |
Readback resolution |
Voltage |
|
1 mV |
Current |
|
100 µA |
Low-current measurement range |
≤ 200 mA output current |
1 µA |
Readback accuracy |
Voltage |
±(% of output + offset) |
R&S NGA101, R&S NGA102 |
< 0.02 % + 5 mV |
Current |
±(% of output + offset) |
< 0.03 % + 500 µA |
Low-current measurement range |
R&S NGA101, R&S NGA102 |
< 0.15 % + 40 µA |
Temperature coefficient (per °C) |
+5 °C to +20 °C and +30 °C to +40 °C |
Voltage |
±(% of output + offset) |
< 0.0075 % + 0.75 mV |
Current |
±(% of output + offset) |
< 0.015 % + 3 mA |
Low-current measurement range |
|
< 0.023 % + 5 µA |
Remote sensing |
Maximum sense compensation |
R&S NGA101, R&S NGA102 |
0.5 V (meas.) |
Ratings |
Maximum voltage to ground |
|
250 V DC |
Maximum counter voltage |
voltage with the same polarity connected to the outputs |
R&S NGA101, R&S NGA102 |
36 V |
Maximum reverse voltage |
voltage with opposite polarity connected to the outputs |
0.4 V |
Maximum reverse current |
for 5 min max. |
6 A |
Remote control |
Command processing time |
|
< 100 ms (typ.) |
Protection functions |
Overvoltage protection |
|
adjustable for each channel |
Programming resolution |
R&S NGA101, R&S NGA102 |
1 mV |
Overpower protection |
|
adjustable for each channel |
Overcurrent protection (electronic fuse) |
|
adjustable for each channel |
Programming resolution |
|
1 mA |
Response time |
(Iload > Iresp × 2) at Iload ≥ 2 A |
< 1 ms |
Fuse linking (FuseLink function) |
R&S NGA101, R&S NGA102 |
yes |
Response time for linked channels |
|
< 5 ms |
Fuse delay time |
adjustable for each channel |
10 ms to 10 s (10 ms increments) |
Overtemperature protection |
independent for each channel |
yes |
Special functions |
Output ramp function |
|
EasyRamp |
EasyRamp time |
|
10ms to 10s (10ms increments) |
Arbitrary function |
CH1 only |
EasyArb |
Parameters |
|
voltage, current, time |
Maximum number of points |
|
128 |
Dwell time |
|
10ms to 600s (10ms increments) |
Repetition |
|
continuous or burst mode with 1 to 255 repetitions |
Trigger |
|
manually, by remote control or via optional trigger input |
Trigger and control interfaces |
R&S NGA-K103 |
digital I/O |
Trigger response time |
|
<100ms |
Maximum voltage (IN/OUT) |
|
5 V |
Input level |
|
TTL |
Maximum drain current (OUT) |
|
5mA |
Data logging |
Maximum acquisition rate |
|
10sample/s |
Memory depth |
|
external USB drive |
Voltage resolution |
|
see readback resolution |
Voltage accuracy |
|
see readback accuracy |
Current resolution |
|
see readback resolution |
Current accuracy |
|
see readback accuracy |
Channel fusion |
Maximum voltage in serial mode |
R&S NGA102 |
70V |
Maximum current in parallel mode |
R&S NGA102 |
12A |
Restricted functions |
|
- EasyRamp
- EasyArb
- Low-current measurement range
- Remote sensing
- Digital I/O
|
General data |
Environmental conditions |
Temperature |
operating temperature range |
+5 °C to +40 °C |
storage temperature range |
-20 °C to +70 °C |
Humidity |
noncondensing |
5 % to 95 % |
Power rating |
Mains nominal voltage |
|
100 V/115 V/230 V (±10 %) |
Mains frequency |
|
50 Hz to 60 Hz |
Maximum power consumption |
|
230 W |
Main fuses |
100 V/115 V AC power source |
5 A, 250 V IEC 60127-2/5 T |
230 V AC power source |
2.5 A, 250 V IEC 60127-2/5 T |
Product conformity |
Electromagnetic compatibility |
EU: in line with Radio Equipment Directive 2014/53/EU |
applied standards:
- ETSI EN 300328 V2.2.2
- EN 61326-1
- EN 61326-2-1
- EN 55011 (Class A)
- EN 55032 (Class A)
- ETSI EN 301489-1 V2.1.1
- ETSI EN 301489-17 V3.1.1
|
|
Korea |
KC mark |
|
USA, Canada |
FCC47 CFR Part 15B, ICES-003 Issue 6 |
Electrical safety |
EU: in line with Low Voltage Directive 2014/35/EU |
applied harmonized standard: EN 61010-1 |
|
USA, Canada |
UL61010-1, CAN/CSA-C22.2 No. 61010-1 |
WLAN approvals |
Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey, United Kingdom |
CE |
|
Singapore |
IMDA standards DB102020 |
|
USA, Canada |
FCC, IC |
RoHS |
in line with EU Directive 2011/65/EU |
EN 50581 |
Mechanical resistance |
Vibration |
sinusoidal |
5 Hz to 55 Hz, 0.3 mm (peak-to-peak), 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 |
random |
8 Hz to 500 Hz, acceleration: 1.2 g (RMS), in line with EN 60068-2-64 |
Shock |
|
40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I |
Mechanical data |
Dimensions |
W × H × D |
222 mm × 97 mm × 448 mm
(8.74 in × 3.82 in × 17.64 in) |
Weight |
R&S NGA102 |
7.0 kg (15.4 lb) |
Rack installation |
R&S HZN96, space for two instruments |
19", 2 HU |
Recommended calibration interval |
operation 40 h/week over entire range of specified environmental conditions |
1 year |