Accurate measurements without the need to precisely position wire or cable in the center of the jaw clamp.SHOP NOW
The SDS3104XHD features an impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding. SHOP NOW
The Megger IMT100 is the most versatile multi-tester for PV systems, electric vehicles and industrial applications.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
0 reviews | Catalog: 3593.8646P96 | UPC: 094308393810 | Model: Rohde & Schwarz HMC8015COM
Package HMC8015 COMPLETE PACKAGE Contains serialized product+options: R and S HMC8015 POWER ANALYZER 3593.8646K02 consisting of: -R and S HMC8015 POWER ANALYZER -R and S HOC151 ADVANCED ANALYSIS -R and S HOC152 ADVANCED I/O -R and S HOC153 COMPLIANCE TEST
Your Price: $4,230.00
Sign-in for EDU Pricing!
Thank you for your interest! Complete the form below and one of our support engineers will contact you directly to coordinate your product demonstration.
Name
Email Address
Phone Number
Which state are you located in?
Thank you!
We've received your request and will be in touch soon.
🤭 Oops there was an error processing your request. Please contact us by phone, chat or email to set-up your demo.
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
(0)
In Stock!
The R&S HMC8015 power analyzer is the first compact tester for AC/DC load and standby current characterization that enables measurements without additional tools such as a computer or remote infrastructure. In addition to a numerical and graphical display with 26 key parameters, the instrument delivers performance and compliance protocols in line with IEC 62301, EN 50564 and EN 61000-3-2. The power analyzer is the only instrument in its class that graphically displays harmonic analysis up to the 50th harmonic on the logarithmic scale. Its user-configurable, dual-channel trend chart function for U, I, P, S, Q and F etc. is unique as well. The instrument's 5 V measurement range provides embedded developers with a previously unattainable level of resolution for power and energy measurements. The R&S HMC8015 also sets new standards when it comes to documentation. It simultaneously displays up to 10 user-configurable measurands with a refresh rate of 10 measurements per second. A logging function makes it possible to store this data with a timestamp in CSV format for a nearly unlimited period of time. Screen content can also be saved to a USB flash drive anytime at the push of a button. A PASS/FAIL function enables users to monitor numerous measurands either on the instrument's display or externally via an analog/digital output on the rear panel. The inrush function captures and graphically displays inrush current and voltage waveforms.
HOC151 / HVC151 Advanced Analysis Option The advanced analysis option complements the base unit's measurands by also displaying peak values for voltage, current and power. These are acquired seamlessly at the full sampling rate of 500 ksample/s. The following additional graphic functions are available.
The inrush function makes it possible to graphically display switch-on behavior (see picture on next page). Triggering can be either manual or edge-based (pos./neg.) when user-defined voltage or current thresholds are reached. 8192 samples are acquired at all times with a logging period of 16 ms to 67 s.
Harmonic analysis can be displayed in a table or graph or even logarithmically for better readability. The bargraph can optionally show up to the 50th harmonic of voltage and/or current. The bargraph shows the amplitude of the harmonic selected with the cursor.
The waveform function shows the voltage, current and power of an input signal period over time. The example shows a load with phase-angle control.
The trend chart function makes it possible to observe longer periods of time and can be displayed on up to two channels. 15 selectable measurands are available, e.g. U, I, P, S, Q, F. The y-axis is scaled in line with progress. The time axis can be varied from 5 s/div to 10 min/div.
The advanced I/O option activates the following additional functions: Sensor input A current-proportional voltage of 100 mV, 1 V or 4 V (full-scale amplitude) can be applied to the sensor input (4 mm safety connectors) in order to significantly expand the power measurement range. Current probes, current transformers and shunts can be connected to the input. The gradient (e.g. mV/A) can be set individually. PASS/FAIL function The PASS/FAIL function can be used to monitor up to six user-defined (upper or lower) limits, which can be selected from a total of 14 measurands (e.g. U, I, P, S, Q, F). The results appear on the display or are transferred to another device connected via the analog or digital output on the rear panel. The analog output delivers voltage proportional to the limits (±5 V). Four BNC ports on the rear panel can be assigned to various sources/sinks. The analog output allows users to choose either limits (PASS/FAIL) or measurands U, I or P as a source. The signal at the analog input (±10 V) can be displayed on the screen with 16-bit resolution as well. The digital output can be assigned to the limit (PASS/FAIL) or the measurement frequency used. The signal at the digital input is available as additional information on the display as status (0/1), frequency (up to 200 kHz) or PWM (0 to 100 %). Both inputs are loggable.
This option includes wizards for the IEC 62301 (standby), EN 50564 (extended standby) and EN 61000-3-2 (harmonic current for EMC, CE approval) standards, making it possible to carry out autonomous measurements without PC. The results are displayed in a table on the screen and can be saved to a USB flash drive in HTML format.
The HZC50 (30 A) and HZC51 (1000 A) AC/DC current probes significantly extend the power measurement range of the R&S HMC8015. Current probes are connected to the sensor input using a 4 mm safety connector. The HZC815 adapter makes it easy and safe to connect a DUT to the R&S HMC8015. The DUT is powered via the appliance coupler on the top of the adapter.
Answers (1) - Asked by Anonymous
I have this question too (0)
The Rohde and Schwarz HMC8015 is available with and without an IEEE-488 (GPIB) interface. •HMC8015, catalog # 3593.8646.02 •Without GPIB interface •HMC8015-G, catalog # 3593.8875.02 •With GPIB interface •HMC8015COM, catalog # 3593.8646P96 •LIMITED TIME PROMOTIONAL PACKAGE •Includes the following •HMC8015 Power analyzer •HOC151 Advanced analysis option •HOC152 Advanced I/O option •HOC153 Compliance test option