Rohde and Schwarz FSL-K72 Specification |
The specifications below are based on the data sheet specifications of the R&S FSL spectrum analyzer and have not been checked separately. Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to and internal calibration performed. Data with tolerances are measurement uncertainties with a confidence level of 95 %. The specified level measurement errors do not take into account systematic errors due to reduced S/N ratio.
PMU = permissible measurement uncertainty in line with test specification 3GPP TS 25.141. |
Frequency error |
Base station output power |
test case 6.2.1 |
Level range |
|
-70 dBm to +30 dBm |
Level uncertainty |
total power Ptotal > -60 dBm |
< 0.5 dB
PMU: < 0.7 dB |
CPICH power accuracy |
test case 6.2.2 |
Level range of total power |
|
-40 dBm to +30 dBm |
Level range of CPICH |
|
-40 dB to 0 dB |
Level uncertainty (absolute power) |
PCPICH ≥ -10 dB |
< 0.52 dB (σ = 0.019)
PMU: < 0.8 dB |
PCPICH ≥ -20 dB |
< 0.59 dB (σ = 0.024) |
Level uncertainty (relative power) |
PCPICH ≥ -10 dB |
< 0.021 dB (σ = 0.006)
PMU: < 0.3 dB |
PCPICH ≥ -20 dB |
< 0.088 dB (σ = 0.022) |
Frequency error |
Frequency error |
test case 6.3 |
Measurement range |
CPICH synchronous |
±5 kHz
PMU: ±1 kHz |
SCH synchronous |
±1 kHz |
Measurement uncertainty |
SNR > 40 dB |
< 5 Hz + Δfref1 (σ = 2 Hz)
PMU: < 12 Hz + Δfref1 |
Output RF spectrum emissions
Measured (R&S FSL) with RBW = 30 kHz, VBW = 300 kHz, OBW = 99 %, SWT = 200 ms, span = 11 MHz |
Occupied bandwidth |
test case 6.5.1 |
R&S FSL |
Measurement uncertainty |
P > -40 dBm, span ≤ 10 MHz |
< 38 kHz (σ = 18 kHz)
PMU: < 100 kHz |
Measured (R&S FSL) with RBW = 30 kHz, VBW = 300 kHz, span = 11 MHz |
Spectrum emission mask |
test case 6.5.2.1 |
Dynamic range |
Ptotal > -20 dBm |
55 dB |
Relative level uncertainty |
|
< 0.25 dB + 2σ (Tsweep)1
PMU: < 1.5 dB |
Absolute level uncertainty |
|
< 0.75 dB + 2σ (Tsweep)1
PMU: < 1.5 dB |
The standard deviation σ (Tsweep) of Gaussian-distributed signals depends on the selected sweep time (Tsweep). Increasing the sweep time decreases the standard deviation (σ). |
Transmit modulation |
Composite EVM |
test case 6.7.1 |
Measurement range |
|
1.0 % to 25 % |
Inherent EVM |
|
< 1.9 % |
Measurement uncertainty |
test models 1 to 5
P > -40 dBm |
< 1 % (σ = 0.3 %)
PMU: < 2.5 % |
Peak code domain error power (PCDEP) |
test case 6.7.2 |
Measurement range |
-50 dB to 0 dB |
0 dB to -50 dB |
Inherent PCDEP |
|
< -50 dB (σ = 0.95 dB) |
Measurement uncertainty |
-30 dB < PCDEP |
< 0.15 dB (σ = 0.05 dB)
PMU: < 1.0 dB |
-40 dB < PCDEP< -30 dB |
< 0.15 dB (σ = 0.05 dB)
PMU: < 1.0 dB |
-50 dB < PCDEP < -40 dB |
< 0.15 dB (σ = 0.05 dB)
PMU: < 1.0 dB |
|
-60 dB < PCDEP < -50 dB |
< 0.15 dB (σ = 0.05 dB)
PMU: < 1.0 dB |
|