Standard Waveforms: Sine, Square, Ramp, Pulse, Noise, Exponential Rise, Exponential Fall, Sinc, Cardiac, DC Waveform Length: 2 to 4K points Non-Volatile Memory: Maximum 4 waveforms Frequency: 500 ?Hz ~ 3 MHz Pulse Width: 20.0 ns to 1999.9 s Vertical Resolution: 14 bits Sample Rate: 100 MSa/s Sine: 1 ?Hz ~ 15 MHz Square: 1 ?Hz ~ 5 MHz Pulse: 500 ?Hz ~ 3 MHz Ramp: 1 ?Hz ~ 150 kHz White Noise: 5 MHz of bandwidth Arbitrary Waveform: 1?Hz ~ 3 MHz Resolution: 1 ?Hz Amplitude (50 O): 20 mVpp to 10 Vpp Accuracy (100 kHz): ? 1% of setting ? 1 mVpp Carrier Waveforms: Sine, Square, Ramp, Arbitrary Waveform Modulating Waveforms: Sine, Square, Ramp, Triangle,Noise, Arbitrary Waveform(2 mHz to 20 kHz) Modulating Depth: 0% ~ 120% Modulating Waveforms: Sine, Square, Ramp, Arbitrary Waveform Modulating Frequency: Sine, Square, Ramp, Triangle,Noise, Arbitrary Waveform(2 mHz to 20 kHz) Deviation: DC to 5 MHz Carrier Waveforms: Sine, Square, Ramp, Arbitrary Waveform Modulating Waveforms: 50% duty cycle Square(2 mHz to 50 kHz) Carrier Waveforms: Sine, Square, Ramp, Arbitrary Waveform Modulating Frequency: Sine, Square, Ramp, Triangle,Noise, Arbitrary Waveform(2 mHz to 20 kHz) Phase Deviation: 0?~ 360? Carrier Waveforms: Sine, Square, Ramp, Arbitrary Waveform Type: Linear or Logarithmic Direction: Up or Down Sweep Time: 1 ms ~ 500 s? 1% Trigger Source: Manual/Internal/External Marker: Fall Edge of Sync Signal(frequency alterable) Waveforms: Sine, Square, Ramp, Pulse, Noise, Arbitrary Waveform Type: count 1 to 50,000 cycles, infinite,gated Start/Stop Phase: -360?~ +360? Internal Period: 1 ?s to 500 s ? 0.1% Gated Source: External Trigger Trigger Source: Manual/Internal/External Measurement Functions: Frequency,Period,Pulse width(positive?negative),Duty cycle Frequency Range: Single channel: 100 mHz ~ 200MHz Frequency Resolution: 6 digit/s Clock Reference: 10 MHz Standard I/O: USB Host,USB Device Internal Help System: Chinese/English Power: Worldwide Use, 100~240 VACRMS/ 40 W Max Weight: 2.7 kg Type: Black and White LCD Screen Resolution: 256 Horizontal x 64 Vertical Grey Degree: 4 Grey Level Contrast (typical): 150 : 1 Light (typical): 300 nit Supply: 100-240 VACRMS, 45-440Hz, CAT II Consumption: Less than 40W Fuse: 2A, T Level , 250V Temperature Range: Operation:10~+40?? Cooling: Natural cooling Humidity Range: Below +35?:=90% relative humidity Height Range: Operation : below 3,000m Width: 232mm Height: 108mm Depth: 288mm Package excluded Weight: 2.65 Kg Package Included Weight: 4Kg IP Protection: IP2X Calibration Interval: One year suggested |