| Analog bandwidth (50 Ω, -3dB) [1] |
2 GHz |
| Analog bandwidth (1 MΩ, -3dB) |
500 MHz |
| Calculated Rising Time under 50 Ω (single-channel mode, 10%-90%, typical) |
≤ 225 ps |
| Max. Sample Rate of Analog Channel |
10 GSa/s (single-channel), 5 GSa/s (half-channel[2]), 2.5 GSa/s (all channels)
Note: When all the channels are enabled, the sample rate is 2.5 GSa/ s, and the max. analog bandwidth reaches 1 GHz. |
5 GSa/s (single-channel), 5 GSa/s (half-channel), 2.5 GSa/s (all channels) |
| Peak Detection |
capture 400 ps glitches |
capture 800 ps glitches |
| Max. Memory Depth |
500 Mpts (single-channel), 250 Mpts (half-channel[2]), 125 Mpts (all channels) |
| Hardware real-time waveform recording and playing |
≥ 450, 000 wfms (single-channel) |
| Max. Waveform Capture Rate[3] |
≥ 600,000 wfms/s |
| No. of Input/Output Channels |
4 input analog channels |
| 1 input EXT channel |
| Arbitrary waveform generator output (required to purchase the DS8000-R-AWG option) |
| Sampling Mode |
Real-time sampling |
| Vertical System Analog Channel |
| Input Coupling |
DC, AC, or GND |
| Input Impedance |
1 MΩ ± 1%, 50 Ω ± 1% |
| Input Capacitance |
19 pF ± 3 pF |
| Probe Attenuation Coefficient |
0.0001X, 0.0002X, 0.0005X, 0.001X, 0.002X, 0.005X, 0.01X, 0.02X, 0.05X, 0.1X, 0.2X, 0.5X, 1X, 2X, 5X, 10X, 20X, 50X, 100X, 200X, 500X, 1000X, 2000X, 5000X, 10000X, 20000X, and 50000X |
| Probe Recognition |
Auto-recognized RIGOL probe |
| Maximum Input Voltage |
1 MΩ |
CAT I 300 Vrms, 400 Vpk, Transient Overvoltage 1600 Vpk |
| 50 Ω |
5VRMS |
| Vertical Resolution |
8 bits |
| Vertical Sensitivity Range[4] |
1 MΩ |
1 mV/div~10 V/div |
| 50 Ω |
1 mV/div~1 V/div |
| Offset Range |
1 MΩ |
±1 V (1 mV/div~50 mV/div)
±30 V (51 mV/div~260 mV/div)
±100 V (265 mV/div~10 V/div) |
| 50 Ω |
±1 V (1 mV/div~100 mV/div)
±4 V (102 mV/div~1 V/div) |
| Dynamic Range |
±5 div(8 bit) |
| Bandwidth Limit (Typical) |
1 MΩ |
20 MHz, 250 MHz, 500 MHz; selectable for each channel |
| 50 Ω |
20 MHz |
| DC Gain Accuracy[4] |
± 2% of full scale |
| DC Offset Accuracy |
>200 mV/div (±0.1 div±2 mV±1.5% of offset value) |
| >200 mV/div (±0.1 div±2 mV±1.0% of offset value) |
| Channel-to-Channel Isolation |
≥ 100:1 (from DC to 1 GHz), ≥ 30:1 (1 GHz to maximum rated bandwidth) |
| ESD Tolerance |
±8 kV (on input BNCs) |
| Horizontal System Analog Channel |
| Range of Time Base |
200 ps/div~1 ks/div |
| Fine |
| Time Base Resolution |
2 ps |
| Time Base Accuracy |
±1 ppm ± 2 ppm/year |
| Time Base Delay Range |
before triggering |
≥ 1/2 screen width |
| after triggering |
1 s or 100 div, whichever is greater |
| Time Interval ( △ T) Measurement |
±(1 sample interval) ± (2 ppm×readout)±50 ps |
| Inter-channel Offset Correction Range |
±100 ns |
| Horizontal Mode |
YT |
Default |
| XY |
X = Channel 1, Y = Channel 2 |
| SCAN |
Time base ≥ 200 ms/div |
| ROLL |
Time base ≥ 200 ms/div |