Measuring parameters |
S11, S21, S22, S12 |
P1dB, 1 dB gain compression |
AM-PM conversion factor |
Error correction |
12 error term full S-parameter correction (insertable DUT) |
12 error term full S-parameter correction (non-insertable DUT) |
8 error term full S-parameter unknown thru correction (non-insertable DUT) |
S11 (1-port correction) |
De-embed (2 embedding networks may be specified), impedance conversion |
S21 (normalize, normalize + isolation) |
S21 (source match correction + normalize + isolation) |
Averaging, smoothing |
Hanning and Kaiser–Bessel filtering on time-domain measurements |
Electrical length compensation (manual) |
Electrical length compensation (auto) |
Effective dielectric constant correction |
Display channels |
4 channels |
Traces |
2 traces per display channel |
Display formats |
Amplitude (logarithmic and linear) |
Phase, Group Delay, VSWR, Real, Imaginary, Smith Chart, Polar, Time Domain |
Memory trace |
One per display channel |
Limit lines |
6 segments per channel (overlap allowed) |
Markers |
8 markers |
Marker functions |
Normal, Δ marker, fixed marker, peak / min. hold, 3 dB and 6 dB bandwidth |
Sweep type |
Linear sweep |
CW sweep (timed sweep) |
Power sweep (P1dB utility) |
Sweep times |
140 kHz bandwidth |
10 MHz to 6 GHz sweep |
201 points (12-term cal): 37 ms |
201 points (S21 cal): 25 ms |
Number of sweep points, VNA mode |
51, 101, 201, 401, 801, 1001, 2001, 4001, 5001, 6001, 7001, 8001, 9001,10001 |
Number of sweep points, TDR mode |
512, 1024, 2048, 4096 |
Frequency range |
300 kHz to 6.0 GHz |
Frequency setting resolution |
10 Hz |
Frequency accuracy |
10 ppm max |
Frequency temperature stability |
±0.5 ppm/ºC max |
Harmonics |
–20 dBc max |
Non-harmonic spurious |
–40 dBc typical |
Phase noise (10 kHz offset) |
–90 dBc/Hz [0.3 MHz to 1 GHz] |
–80 dBc/Hz [1 GHz to 4 GHz] |
–76 dBc/Hz [> 4 GHz] |
Test signal power |
F < 10 MHz: |
10 MHz < F < 4 GHz: |
F > 4 GHz: |
Power setting resolution |
0.1 dB |
Power setting accuracy |
±1.5 dB |
Reference input frequency |
10 MHz ±6 ppm |
Reference input level |
0 ±3 dBm |
Reference output level |
0 ±3 dBm |
Controlling PC data interface |
USB 2.0 |
Support for third party test software |
Dynamic Link Library (DLL) as part of user interface software |
External dimensions (mm) |
286 x 174 x 61 (L x W x H) |
Excluding connectors |
Warranty |
3 years |
Weight |
1.85 kg |
Temperature range (operating) |
+15 °C to +40 °C |
Temperature range (storage) |
–20 °C to +50 °C |
Humidity |
80% max, non-condensing |
Vibration (storage) |
0.5 g, 5 Hz to 300 Hz |
Power source and current |
+12 to +15 V DC, 22 W |
Power source connector |
5.5 mm diameter hole, 2.1 mm diameter centre contact pin. |
Center pin is positive. |
Host PC requirements |
Microsoft Windows 7, 8 or 10 |
2 GB RAM or more |