General Specifications |
Model |
PicoScope 4424 |
PicoScope 4224 |
PicoScope 4224 IEPE |
Passive probe
mode |
IEPE interface
mode |
Oscilloscope – vertical |
Input channels |
2 |
2 |
Bandwidth |
10 MHz |
1.6 Hz to 20 MHz |
(10 MHz on ±50 mV range) |
Rise time (10% to 90%,
calculated) |
17.5 ns (35 ns on ±50 mV range) |
Input type |
Single–ended, BNC connector |
Vertical resolution |
12 bits |
Enhanced vertical resolution |
16 bits |
Input sensitivity |
10 mV/div to 20 V/div |
10 mV/div to 4 V/div |
Input ranges (full scale) |
±50 mV to ±100 V in 11 ranges |
±50 mV to ±20 V in 9 ranges |
Input coupling |
Software-selectable AC/DC |
Input characteristics |
1 MΩ || 22 pF |
1 MΩ || 1 nF |
DC accuracy |
±1% |
Overvoltage protection |
±200 V (DC + AC peak) |
±100 V (DC + AC peak) |
Oscilloscope — horizontal |
Maximum sampling rate (single
shot) |
1 or 2 channels:
80 MS/s*
3 or 4 channels:
20 MS/s |
80 MS/s |
* To achieve the stated sampling rate with two channels, enable one
channel from A or B and one from C or D. |
Maximum sampling rate
(continuous streaming mode) |
10 MS/s (Record length limited to 20 MS in PicoScope, unlimited when using
the supplied SDK) |
Timebase ranges |
100 ns/div to 5000 s/div |
Buffer memory |
32 M samples shared between active channels |
Maximum buffer segments |
10,000 |
Timebase accuracy |
50 ppm with ≤10 ps jitter |
Triggers |
Source |
Any input channel |
Trigger modes |
Free run, auto, repeat, single, rapid (segmented memory) |
Trigger types |
Rising edge, falling edge, edge with hysteresis, pulse width, runt pulse,
dropout, logic, windowed |
Trigger level |
Adjustable over whole of selected voltage range |
Trigger sensitivity |
Digital triggering provides 1 LSB accuracy up to full bandwidth. |
Maximum pre-trigger capture |
10 x “per division” timebase setting |
Maximum post-trigger delay |
50 s |
Spectrum analyzer |
Frequency range |
DC to 20 MHz |
Display modes |
Magnitude, peak hold, average |
Windowing functions |
Blackman, Gaussian, triangular, Hamming, Hann, Blackman–Harris, flat–top,
rectangular |
Number of FFT points |
Selectable from 128 to 1 million in powers of 2 |
Scale / units |
X axis : linear or log 10
Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts) |
Math channels |
Functions |
−x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan,
arcsin, arccos, arctan, sinh, cosh, tanh, freq, derivative, integral, min, max,
average, peak, delay |
Operands |
A, B (input channels), T (time), reference waveforms, constants, pi |
Automatic measurements |
Oscilloscope mode |
AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time,
frequency, high pulse width, low pulse width, maximum, minimum, peak to
peak, rise time, rising rate. |
Spectrum mode |
Frequency at peak, amplitude at peak, average amplitude at peak,
total power, THD %, THD dB, THD plus noise, SFDR, SINAD, SNR, IMD |
Statistics |
Minimum, maximum, average and standard deviation |
Serial decoding |
Protocols |
CAN, LIN, I²C, UART/RS-232, SPI, I²S, FlexRay |
Inputs |
All input channels with any mixture of protocols |
Mask limit testing |
Mask generation |
Auto generate from captured waveform, manual drawing, manual
coordinate entry |
Actions |
Highlight on screen, select in buffer overview, activate alarm |
Statistics |
Pass/fail, failure count, total count |
Alarms |
Initiating events |
Capture, buffer full, mask fail |
Alarm actions |
Beep, play sound, stop/restart capture, run executable, save current
buffer/all buffers, trigger signal generator |
Display |
Interpolation |
Linear or sin(x)/x |
Persistence modes |
Digital color, analog intensity, fast, custom |
Data export |
Output file formats |
BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope
settings, TXT |
Output functions |
Copy to clipboard, print |
Environmental |
Temperature range (operating) |
0 °C to 45 °C |
Temperature range (stated
accuracy) |
20 °C to 30 °C |
Temperature range (storage) |
-20 to +60°C |
Humidity range (operating) |
5% to 80% RH, non–condensing |
Humidity range (storage) |
5 to 95% RH, non–condensing |
Physical properties |
Dimensions |
200 x 140 x 35 mm (approx 7.9 x 5.5 x 1.4 in) |
Weight |
<500 g (approx 1.1 lb) |
PC requirements |
Minimum |
Processor: 1 GHz
Memory: 512 MiB
Free disk space: 32–bit: 600 MB, 64–bit: 1.5 GB
Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT)
Ports: USB 1.1 port (will result in significantly reduced performance) |
Recommended |
Processor: 1 GHz
Memory: 512 MiB
Free disk space: 32–bit: 850 MB, 64–bit: 2 GB
Operating system: 32– or 64–bit edition of Microsoft Windows 7 or Windows 8 (not Windows RT)
Ports: USB 2.0 (or higher) port |
Software |
Software included |
PicoScope 6 for Windows oscilloscope software |
Optional free software |
PicoScope 6 Beta for Linux and OS X. Drivers for Linux and OS X. |
Languages |
Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English,
Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean,
Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish,
Turkish |
General |
Additional hardware (supplied) |
USB 2.0 cable, user manuals |
PC requirements |
Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows
RT). |
PC connectivity |
USB 2.0 port (compatible with USB 1.1 and USB 3.0; USB 1.1 not
recommended) |
Power requirements |
Powered from USB port |
Safety approvals |
European LVD standard |
EMC approvals |
European EMC standard
FCC Rules Part 15 Class A |
Environmental approvals |
RoHS compliant |
Total satisfaction guarantee |
In the event that this product does not fully meet your requirements you
can return it for an exchange or refund. To claim, the product must be
returned in good condition within 14 days. |
Warranty |
5 years |