With a century of knowledge and product research behind them, Enerpac, best known for its hydraulic tools, can be your go-to for thousands of applications across every industry. SHOP NOW
Get up to 15% off with the FLIR Ex-Series sale! These cameras are powerful troubleshooting tools for building, electrical, and mechanical applications. With various available models, you can fit your target size, working distance, visual detail needs, and budget.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
0 reviews | Catalog: 0850555 | Model: Oakton WD-08505-55
Digi-Sense Type-J, Small-Diameter Standard Probe, Mini-Connector, 4 in. L, .063 Dia, Grounded
List Price: $79.90
Your Price: $66.58
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
The Oakton Thermocouple probes were designed to measure any general-purpose or liquid immersion application. All thermocouple probes include a 5-ft. PVC coiled cord with strain relief that protects from repeated flexing and tugging. Finger stops on handle prevent probe from rolling and fingers from sliding when inserting probe into hard materials. Rugged plastic mini connector is compatible with all Oakton Digi-Sense and Acorn thermocouple thermometers.
Thermocouple Probe Junction Types Sheaths with small diameters have faster response times; sheaths with larger diameters have longer life and are better for measuring higher temperatures.
Exposed Junction has the fastest response time ideal for measuring rapid temperature changes. Clear coating on most models provides a humidity barrier for the thermocouple. Do not use with corrosive fluids or atmospheres.
Ungrounded Junction has a welded junction insulated from the protective sheath and is electrically isolated. Longer response time; use for conductive solutions or where isolation of the measuring circuitry is required.
Grounded Junction has a junction welded to tip of sheath. Wires are completely sealed from contaminants. Good response time.
Inconel® 600 Sheath is ideal for severely corrosive environments and elevated temperatures. Resists progressive oxidation. Maximum operating temperature: 1148°C (2100°F) continuous; 1371°C (2500°F) intermittent. 304 SS Sheath is for general-purpose use, is corrosion-resistant, and good for food service and biological applications. Maximum operating temperature: 898°C (1650°F) continuous; 1398°C (2550°F) intermittent. 316 SS Sheath has higher corrosion resistance than 304 SS. Withstands some strong acids. Maximum operating temperature: 898°C (1650°F) continuous; 1371°C (2500°F) intermittent. SS Sheath with Coating of PTFE or PFA with grounded junction is ideal with corrosive liquids and atmospheres. Longer response time. Temperatures to 260°C (500°F). Polymer Body Probes are available in a variety of polmyers including Kapton® and PTFE. These provide excellent flexibility and often good chemical resistance. Be sure to consult a chemical compatibility table when selecting a probe for your application.
Extend Your Thermocouples up to 2000 feet without signal loss. Extension wire must be the same type as the thermocouple. System Error becomes important when you select a probe and meter to make a complete temperature measurement system. For example: a meter has an accuracy of ±0.7°F; probe error for the type T probe with metal sheath, straight cable, and stripped ends will have an error limit of ±1.8°F at 400°F. Therefore, the probe-meter system accuracy will be (±0.7) + (±1.8) = ±2.5°F at 400°F. NIST traceability is required for many applications. In order to make an item traceable to NIST standards, the item and the standard are exposed to the same conditions, the readings are noted, and the difference between the readings is recorded on a NIST-traceable calibration report. When taking future readings with the item, the value on the report must be added or subtracted from the measured value.
Stainless steel sheaths provide good chemical resistance and fast thermal response These thermocouple probes were designed to measure any general-purpose or liquid immersion application. All thermocouple probes include a 5-ft PVC coiled cord with strain relief that protects from repeated flexing and tugging. Ergonomic, easy-grip 5"L glass-filled nylon handle (unless noted below) provides maximum heat insulation and impact resistance. Fingerstops on handle prevent probe from rolling and fingers from sliding when inserting probe into hard materials.
The 316 stainless steel sheath (shaft casing) provides durability, strength, and maximum abrasion resistance. Rugged thermoset plastic miniconnector is compatible with all Oakton and Acorn ® thermocouple thermometers. Connectors and coiled cord are color-coded based on type: type J black, type K yellow, and type T blue.
Please select a rating star.
Please complete this field.
Email Adrress is not Valid.
Almost there, please complete all required fields
Out of 5
Average Customer Review