General Specifications |
Dimensions |
4.05 in x 7.67 in x 2.16 in (10.3 cm x 19.5 cm x 5.5 cm) |
Weight |
1.677 lbs. (0.76 kg) |
Battery |
Removable, rechargeable lithium-ion battery pack (7.2 V, 6.4 A, 46 Wh) |
Battery Life |
Typical operating life is 6 hours; Typical charge time is 3 hours |
Display |
5.0-inch color LCD with capacitive touchscreen (720 x 1280 pixels) |
Host Interface |
RJ-45 Cable Test and Management Port
USB Type-A Port
USB Type-C On-the-Go Port |
SD Card Port |
Supports Micro SD card storage |
Memory |
Approximately 8 GB available for storing test results and user applic-ations |
Charging |
USB Type-C 45-W adapter:
AC Input Power 100-240 V, 50-60 Hz; DC Output Power 15 V (3 A)
RJ-45: 802.3at and 802.3bt PoE |
Media Access |
Copper: 10M/100M/1G/2.5G/5G/10G
Fiber SFP Adapters: 1G/10GBASE-X |
Supported IEEE
Standards |
Wired: 802.3/ab/ae/an/bz/i/u/z Wi-Fi: 802.11a/b/g/n/ac
PoE: 802.3af/at/bt, Class 0-8 and UPOE |
Cable Test |
Pair lengths, opens, shorts, splits, crossed, straight through, and WireView ID |
Wireless |
EtherScope nXG has two internal Wi-Fi Radios: |
Wi-Fi Testing – 4x4 Dual-band 802.11ac Wave 2 wireless radio Android System Wi-Fi, Bluetooth, and Management – 1x1 Dual-band 802.11ac Wave 2 + Bluetooth 5.0 and BLE wireless radio (Both are IEEE 802.11a/b/g/n/ac compliant.) |
Environmental |
Operating Temperature |
32°F to 113°F (0°C to +45°C)
NOTE: The battery will not charge if the internal temperature of the tester is above 122°F (50°C). |
Operating relative humidity (% RH without condensation) |
90% (50°F to 95°F; 10°C to 35°C)
75% (95°F to 113°F; 35°C to 45°C) |
Storage temperature |
-4°F to 140°F (-20°C to +60°C) |
Shock and vibration |
Meets the requirements of MIL-PRF-28800F for Class 3 Equipment |
Safety |
IEC 61010-1:2010: Pollution degree 2 |
Altitude |
Operating: 4,000 m; Storage: 12,000 m |
EMC |
IEC 61326-1: Basic Electromagnetic Environment;
CISPR 11: Group 1, Class A |
Certifications and Complaince |
Conforms to relevant European Union
Conforms to relevant Australian Safety and EMC standards.
Complies with 47 CFR Part 15 requirements of the U.S. Federal Communications Commission.
Listed by the Canadian Standards Association |