Conductivity/TDS Digital Monitor Only, 0-2000 µS, 4-20 mA Module, 115VAC Power cord
The Myron L 759II-121-4A-PC is a 750II series digital conductivity/TDS monitor only (no controller) with a range of 0-2000 µS, 4-20 mA self-powered isolated output module, and 115VAC power cord (8-ft/2.44 meters with plug and strain relief).
The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by field-proven electronics, including automatic DC offset compensation and highly accurate drive voltage. Since temperature compensation is at the heart of accurate water measurement, all Myron L Monitor/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models were corrected to 25°C. The TC may be disabled to conform with USP requirements.
All 750 Series II models feature an IP65/ NEMA 4X water-resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench, or surface mounting.