Model Number Description Your Price Purchase
M1500-DI0030-03-2-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-03-2-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-03-2-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-03-2-4port 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-0-01 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0030-04-0-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0030-04-0-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-04-0-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-04-1 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-1-01 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-1-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-1-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-04-1-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-04-1-4port 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-2 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-2-01 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-2-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-04-2-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-04-2-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-04-2-4port 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-0-01 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0030-05-0-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0030-05-0-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-05-0-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-05-1 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-1-01 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-1-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-1-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-05-1-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-05-1-4port 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-2 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-2-01 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-2-01-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0030-05-2-02 0 TO 30 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-05-2-02-4P 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0030-05-2-4port 0 TO 30 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100 0 TO 100 PSI Differential, Isolated, 2-port manifold N/A

Discontinued

M1500-DI0100-01-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, RS-232 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0100-01-0-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-01-0-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0100-01-0-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration N/A

Discontinued

M1500-DI0100-01-1 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-01-1-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0100-01-1-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-01-1-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0100-01-1-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-01-1-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-01-2 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-01-2-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-01-2-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-01-2-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-01-2-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-01-2-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, RS-485 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0100-02-0-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-02-0-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0100-02-0-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order)Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-02-1 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-1-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0100-02-1-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-1-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0100-02-1-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order)Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-02-1-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-2 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-2-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-2-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-02-2-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-02-2-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-02-2-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, USB 2.0 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0100-03-0-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-03-0-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0100-03-0-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-03-1 0 TO 100 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-1-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0100-03-1-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-1-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 100 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0100-03-1-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-03-1-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-2 0 TO 100 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-2-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-2-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-03-2-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-03-2-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-03-2-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-0-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-04-0-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-04-0-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-04-0-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-04-1 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-1-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-1-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-1-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-04-1-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-04-1-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-2 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-2-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-2-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-04-2-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-04-2-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-04-2-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-0-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-05-0-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0100-05-0-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-05-0-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-05-1 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-1-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-1-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-1-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-05-1-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-05-1-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-2 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-2-01 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-2-01-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0100-05-2-02 0 TO 100 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-05-2-02-4P 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0100-05-2-4port 0 TO 100 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300 0 TO 300 PSI Differential, Isolated, 2-port manifold N/A

Discontinued

M1500-DI0300-01-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, RS-232 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0300-01-0-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-01-0-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0300-01-0-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration N/A

Discontinued

M1500-DI0300-01-1 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-01-1-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0300-01-1-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-01-1-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0300-01-1-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-01-1-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-01-2 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-01-2-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-01-2-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-01-2-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-01-2-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-01-2-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-232 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, RS-485 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0300-02-0-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-02-0-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0300-02-0-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order)Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-02-1 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-1-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0300-02-1-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-1-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0300-02-1-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order)Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-02-1-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-2 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-2-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-2-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-02-2-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-02-2-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-02-2-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - RS-485 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, USB 2.0 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0300-03-0-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-03-0-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0300-03-0-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-03-1 0 TO 300 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-1-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: None. N/A

Discontinued

M1500-DI0300-03-1-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-1-02 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 300 PSI Differential, Isolated, 2-port manifold, 4-20 mA DC or 0 to 5 V DC Analog Output, 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB, Factory Configuration Options: Custom. N/A

Discontinued

M1500-DI0300-03-1-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-03-1-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-2 0 TO 300 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-2-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-2-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-03-2-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-03-2-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-03-2-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - USB 2.0 Digital Communication, 0.025% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-0-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-04-0-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-04-0-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-04-0-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-04-1 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-1-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-1-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-1-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-04-1-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-04-1-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-2 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-2-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-2-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-04-2-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-04-2-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-04-2-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 4-20 mA DC Analog Output (includes RS-485 comm.), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-0-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-05-0-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Standard Configuration N/A

Discontinued

M1500-DI0300-05-0-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-05-0-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, 4-20 mA or 0-5 V output - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-05-1 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-1-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-1-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-1-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-05-1-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-05-1-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, MSP (Meriam Serial Protocol): RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-2 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-2-01 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-2-01-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0300-05-2-02 0 TO 300 PSI Differential, Isolated, 2-port manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-05-2-02-4P 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Custom Factory Configuration (Customer must complete and submit M1500 Configuration Sheet Z9R114 with order) N/A

Discontinued

M1500-DI0300-05-2-4port 0 TO 300 PSI Differential, Isolated, 4-port, flushing manifold - 0-5 V DC Analog Output (includes RS-485 comm), 0.035% FS, Modbus RTU: RS-232, RS-485 or USB - Standard Configuration N/A

Discontinued

M1500-DI0500 0 TO 500 PSI Differential, Isolated, 2-port manifold N/A

Discontinued

M1500-DI0500-01-0-01 Transmitter Accuracy: 0.025% FS (RS-232, RS-485 & USB only-see Analog accuracy below), 0 TO 500 PSI Differential, Isolated, 2-port manifold, RS-232 Digital Communication, 0.025% FS, Not applicable: 4-20 mA or 0-5 V output, Factory Configuration Options: None. N/A

Discontinued

X