MT8530: Trinocular Metallurgical Brightfield /Darkfield Compound Microscope with Incident (Reflected) light BF/DF and Transmitted light BF/DF and simple Polarization Observation. ∞ Infinity Corrected optical system F-200MM. Vertical Köhler illuminator , with infinity tube lens, focal length 200mm, 12V 50W Halogen lamp with clear blue, clear green, ND 25, neutral density filter, and polarizing filters in metal mounts and Transmitted Kohler 6V 30W Halogen and simple polarization with quadruple nosepiece and auto voltage sensing power supply 110-240V. Ceramic Coated, flat-top stage, 191mm X 126mm with 100mm X 100mm travel.
MA816: Trinocular head - Siedentopf type, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0 mm I.D. eyetube). Inclined at 30° degrees (Included in Model MT8530 and MT8530L)
MA817 (x 2): SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm (each) (MA817 accepts optional 25mm diameter reticle)
MA906 (x 2): Eyeshield for MA817 SWH 10X eyepiece (each)
MA923: Plan Epi Objective BD 5X, N.A. 0.10, W.D. 17.0 mm, F.N. 22, ∞ Infinity Corrected
MA924: Plan Epi Objective BD 10X, N.A. 0.25, W.D. 7.48 mm, F.N. 22, ∞ Infinity Corrected
MA925: Plan Epi Objective BD 20X, N.A. 0.40, W.D. 5.20 mm, F.N. 22, ∞ Infinity Corrected
MA926: Plan Epi Objective BD 50X, N.A. 0.75, W.D. 0.38 mm, F.N. 22, ∞ Infinity Corrected
MA928:Vertical Köhler illuminator, with infinity tube lens, focal length 200mm, 12V 50W halogen lamp with clear blue, clear green, ND 25, neutral density filter, and polarizing filters in metal mounts. 100V~240V (requires MA928/05)
MA928/05: Electronic external transformer with automatic voltage sensing capability for MA928 in separate case (Input 100V~240V, Output 12V 50W) (Included on Halogen models only)
MA942: Ceramic Coated, flat-top stage, 191mm X 126mm with 100mm X 100mm travel. Equipped with precision ball bearing quides and low positioned drop down coaxial controls for X-Y movement and 94.5mm circular glass insert stage plate. (Included in Model MT8520 and MT8530) (Factory Installed)
Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns per division. Range of travel is 23mm. Incorporates tension adjustment and safety Auto-focus stage stop lever. (Factory Installed)
MA275/25: Blue clear filter, 19.5mm diameter filter in metal mount, fits 30mm filter slot
MA275/30: Green clear filter, 19.5mm diameter filter in metal mount, fits 30mm filter slot
MA275/50: N.D.50 neutral density filter, 19.5mm diameter filter in metal mount, fits 30mm filter slot
MA959: Polarizing filter, 19.5mm diameter filter in metal mount, fits 30mm filter slot
MA910/05: Substage condenser with iris diaphragm, dovetail mount
MA275/05: Bulb 12V 50W Halogen lamp (Incident light)(Factory Installed)
MA326: Bulb 6V 30W Halogen lamp (Transmitted light)(Factory Installed)
MA327: Fuse 3A for transmitted light Halogen Illuminator(Factory Installed)
MA809/10: Removable AC Electric cord with plug for 115V Models (Included in all 115V models) or
MA809/20: Removable AC Electric cord with plug for 220V Models (Included in all 220V models)
MA709: Dust cover for all MT8500 Series models
Manual: Meiji Techno America MT8500 Manual
Warranty: Limited Lifetime Warranty Card