| OUTPUT |
| Output Volt Amp Capacity (VA) |
500 |
| Output Watt Capacity (Watts) |
300 |
| Power Factor |
0.6 |
| Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
| Nominal Voltage Details |
230v nominal inverter output voltage |
| Frequency Compatibility |
50 / 60 Hz |
| Output Voltage Regulation (Line Mode) |
-8%, +15% |
| Output Voltage Regulation (Battery Mode) |
+/- 5% |
| Output Receptacles |
(7) C13 |
| Included Output Power Cables |
Two 1.8m IEC320-C13 to C14 load jumper cables |
| UPS Output Receptacles (Surge Suppression Only) |
6 UPS outlets, 1 surge-only outlet |
| Load Management Receptacles |
One switchable single-outlet C13 load bank |
| Hot-Swap PDU options |
PDUBHV10 (2U / 8 C13 outlets) |
| Output AC Waveform (AC Mode) |
Sine wave |
| Output AC Waveform (Battery Mode) |
PWM sine wave |
| INPUT |
| Rated input current (Maximum Load) |
2.4A |
| Nominal Input Voltage(s) Supported |
230V AC |
| UPS Input Connection Type |
C14 inlet |
| UPS Input Connection Description |
C14 inlet accepts user-supplied AC power cord with country-specific plug |
| Input Circuit Breakers |
8A |
| Input Phase |
Single-Phase |
| BATTERY |
| Full Load Runtime (min.) |
3.2 min. (300w) |
| Half Load Runtime (min.) |
14.6 min. (150w) |
| DC System Voltage (VDC) |
12 |
| Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
| Internal UPS Replacement Battery Cartridge |
RBC62-1U |
| Battery Access |
Battery access door |
| Battery Replacement Description |
Hot-swappable, user replaceable batteries |
| Expandable Runtime |
No |
| VOLTAGE REGULATION |
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 187 |
| Undervoltage Correction |
Input voltages between 187 and 207 are boosted by 14% |
| USER INTERFACE, ALERTS & CONTROLS |
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| SURGE / NOISE SUPPRESSION |
| UPS AC Suppression Joule Rating |
480 joules |
| EMI / RFI AC Noise Suppression |
Yes |
| PHYSICAL |
| Included Mounting Accessory Description |
Included mounting flanges support rackmount installation in 2 or 4 post racks |
| Primary Form Factor |
Rackmount |
| UPS Power Module Dimensions (hwd, cm) |
4.39 x 43.99 x 29.49 |
| Rack Height (U Spaces) |
1 |
| Minimum Required Rack Depth (cm) |
35.31 |
| UPS Power Module Weight (kg) |
8.16 |
| UPS Shipping Dimensions (hwd / cm) |
12.70 x 57.15 x 40.64 |
| Shipping Weight (kg) |
9.5 |
| UPS Housing Material |
Steel |
| Minimum Required Rack Depth (mm) |
353 |
| Primary UPS Height (mm) |
44 |
| Primary UPS Width (mm) |
440 |
| Primary UPS Depth (mm) |
295 |
| Shipping Height (mm) |
127 |
| Shipping Width (mm) |
572 |
| Shipping Depth (mm) |
406 |
| ENVIRONMENTAL |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity |
0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) |
33 |
| Battery Mode BTU / Hr. (Full Load) |
360 |
| AC Mode Efficiency Rating (100% Load) |
95% |
| COMMUNICATIONS |
| Communications Interface |
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Network Management Cards |
SNMPWEBCARD; TLNETCARD; WEBCARDLX |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports |
| Communications Cable |
USB and DB9 cabling included |
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Network UPS Tools Compatibility |
NUT compatible |
| LINE / BATTERY TRANSFER |
| Transfer Time |
2-4 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) |
187 |
| High Voltage Transfer to Battery Power (Setpoint) |
264 |
| SPECIAL FEATURES |
| Grounding Lug |
Back panel grounding lug |
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| High Availability UPS Features |
Hot swappable batteries |
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| CERTIFICATIONS |
| UPS Certifications |
CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina); ROHS (Restriction of Hazardous Substances) |
| UPS Certification Details |
CE: EC62040 |
| WARRANTY |
| Product Warranty Period (International) |
2-year limited warranty |
| Product Warranty Period (Mexico) |
2-year limited warranty |
| Product Warranty Period (Puerto Rico) |
2-year limited warranty |