OUTPUT Output Volt Amp
Capacity (VA) |
1200 |
Output kVA capacity
(kVA) |
1.2 |
Output Watt Capacity
(watts) |
700 |
Nominal Output
Voltage(s) Supported |
115v; 120v |
Frequency
compatibility |
60 Hz |
Output voltage
regulation (line mode) |
-18%, +8% |
Output voltage
regulation (Battery
mode) |
115V (+/- 5%) |
Built-in UPS output
receptacles |
8 5-15R outlet(s) |
Basic PDU options |
PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDU1415 (0U / 14 5-15R outlets);
PDUV15 (0U / 12 5-15R outlets) |
Metered PDU options |
PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*; PDUMV15 (0U / 16 5-15R outlets) |
Switched PDU options |
PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U / 16 5-15R outlets) |
External PDU
redundancy options * |
Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS
models only |
Output AC waveform
(AC mode) |
Sine wave |
Output AC waveform
(battery mode) |
PWM sine wave |
INPUT |
Rated input current (at
maximum load) |
7A |
Nominal Input
Voltage(s) Supported |
120V AC |
UPS input connection
type |
5-15P; Space saving right angled input plug |
Input circuit breaker |
10A |
UPS Input cord length
(ft.) |
6 |
UPS Input cord length
(m) |
1.8 |
Recommended
Electrical Service |
15A 120V |
BATTERY |
Full load runtime
(minutes) |
4 min. (700w) |
Half load runtime
(minutes) |
12 min. (350w) |
DC system voltage |
24V DC |
Battery recharge rate
(included batteries) |
Less than 4.5 hours from 10% to 90% |
VOLTAGE REGULATION |
Voltage regulation
description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage correction |
Input voltages between 128 and 147 are reduced by 12% |
Undervoltage
correction |
Input voltages between 93 and 107 are boosted by 14% |
Severe undervoltage
correction |
Input voltages between 75 and 92 are boosted by 30% |
LEDS ALARMS & SWITCHES |
LED Indicators |
Front panel LCD display |
Front panel LCD
display |
Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace
battery status; LCD screen rotates for rack/tower viewing |
Alarms |
Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert
software |
Alarm cancel operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status |
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness |
SURGE / NOISE SUPPRESSION |
UPS AC suppression
joule rating |
480 |
UPS AC suppression
response time |
Instantaneous |
UPS Dataline
suppression |
1 line TEL / DSL or 10Base T Ethernet protection |
EMI / RFI AC noise
suppression |
Yes |
PHYSICAL |
Installation form
factors supported with
included accessories |
4 post 19 inch rackmount (mounting kit included); 2 post 19 inch rackmount (mounting kit included) |
Included mounting
accessory description |
Pair of mounting ears enable tower and 2-4 post rackmount installation |
Primary form factor |
Rackmount |
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches) |
3.5 x 17.2 x 10.5 |
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / cm) |
8.9 x 43.8 x 26.7 |
Installed whole
system maximum rack
depth (inches) |
10.5 |
Installed whole
system maximum rack
depth (cm) |
26.7 |
Installed whole
system total rack
space height (rack
spaces) |
2U |
Secondary form factor |
Tower |
Installed whole
system dimensions in
secondary form factor
(height x width x
depth / inches) |
17.2 x 3.5 x 10.5 |
UPS dimensions in
secondary form factor
(height x width x
depth / cm) |
43.8 x 8.9 x 26.7 |
UPS / Power Module
weight (lbs) |
29.4 |
UPS / Power Module
weight (kg) |
13.3 |
UPS Shipping
dimensions (height x
width x depth / inches) |
7.5 x 15 x 21.5 |
UPS Shipping
dimensions (height x
width x depth / cm) |
19 x 38.1 x 54.6 |
Shipping weight (lbs) |
29.4 |
Shipping weight (kg) |
13.3 |
UPS housing material |
ABS |
ENVIRONMENTAL |
Operating
Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature
Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC mode BTU / hr.
(full load) |
179.1 |
Battery mode BTU / hr.
(full load) |
487.5 |
COMMUNICATIONS |
Communications
interface |
USB (HID enabled); DB9 Serial |
Network monitoring
port description |
Supports detailed monitoring of UPS and site power conditions |
PowerAlert software |
Free download from www.tripplite.com |
Communications cable |
USB and DB9 Serial cabling included |
WatchDog
compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER |
Transfer time |
2-4 milliseconds |
Low voltage transfer
cto battery power
c(setpoint) |
75 |
High voltage transfer
cto battery power
(setpoint) |
147 |
SPECIAL FEATURES |
Cold Start (startup in
cbattery mode during a power failure) |
Cold-start operation supported |
CERTIFICATIONS UPS Certifications |
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B
c(EMI); Meets FCC Part 68 / Industrie Canada (telecommunications); ROHS (Reduction of Hazardous Substances) |