Vertical System |
Analog Bandwidth @ 50 Ω (-3 dB) |
1 GHz (≥ 2 mV/div) |
Analog Bandwidth @ 1 MΩ (-3 dB) |
500 MHz (typical) |
Rise Time (10–90%, 50 Ω) |
415 ps (typical) |
Input Channels |
4 |
Vertical Resolution |
8-bits; up to 11-bits with enhanced resolution (ERES) |
Sensitivity |
50 Ω: 1 mV/div–1 V/div, fully variable; 1 MΩ: 1 mV/div–10 V/div, fully variable |
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) |
±1% F.S. (typical), offset at 0 V |
Channel-Channel Isolation |
DC up to rated BW: 40 dB (>100:1), (For any two ProBus input channels, same v/div settings, typical) |
Offset Range |
50 Ω:
±1.6 V @ 1 mV– 4.95 mV/div, ±4 V @ 5 mV–9.9 mV/div,
±8 V @ 10 mV–19.8 mV/div, ±10 V @ 20 mV–1 V/div
1 MΩ:
±1.6 V @ 1 mV–4.95 mV/div, ±4 V @ 5 mV–9.9 mV/div,
±8 V @ 10 mV–19.8 mV/div, ±16 V @ 20 mV–100 mV/div
±80 V @ 102 mV–1.0 V/div, ±160 V @ 1.02 V–10 V/div |
DC Vertical Offset Accuracy |
±(1.5% of offset setting +1% of full scale + 1 mV) (test limit) |
Maximum Input Voltage |
50 Ω: 5 Vrms ±10 V peak; 1 MΩ: 400 V max. (DC + peak AC < 10 kHz) |
Input Coupling |
1 MΩ: AC, DC, GND; 50 Ω: DC, GND |
Input Impedance |
50 Ω ±2% or 1 MΩ || 17pF, 10 MΩ || 9.5 pF with supplied Probe |
Bandwidth Limiters |
20 MHz, 200 MHz |
Horizontal System |
Timebases |
Internal timebase common to 4 input channels; an external clock may be applied at the EXT input |
Acquisition Modes |
Real-time, Roll, Random Interleaved Sampling (RIS), Sequence |
Time/Division Range |
200 ps/div - 1000 s/div (more on data) |
Clock Accuracy |
≤ 1.5 ppm +(aging of 0.5 ppm/yr from last calibration) |
Sample Clock Jitter |
Up to 10μs Acquired Time Range: 100fsrms (Internal Timebase Reference)
Up to 10ms Acquired Time Range: 360fsrms (Internal Timebase Reference) |
Delta Time Measurement Accuracy |
√ 2 * √ (Noise / Slewrate)2 + (Sample Clocl Jitter)2 (RMS) + (clock accuracy * reading) (seconds) |
Jitter Measurement Floor |
√ (Noise/SlewRate)2 + (Sample Clock Jitter)2 (RMS, seconds, TIE) |
Channel-Channel Deskew Range |
±9 x time/div. setting, 100 ms max., each channel |
|
Sample Rate (Single-Shot) |
10 GS/s on 4 Ch |
Sample Rate (Repetitive) |
50 GS/s for repetitive signals (20 ps/div to 10 ns/div) |
Memory Length (# of Segments in Sequence Mode) |
16M / 32M / 32M (5,000) |
Intersegment Time |
1 μs |
Averaging |
Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps |
Enhanced Resolution (ERES) |
From 8.5 to 11 bits vertical resolution |
Envelope (Extrema) |
Envelope, floor, or roof for up to 1 million sweeps |
Interpolation |
Linear or Sin x/x |
Triggering System |
Modes |
Normal, Auto, Single, and Stop |
Sources |
Any input channel, Ext, Ext/10, or line; slope and level unique to each source (except line trigger) |
Coupling Mode |
DC, AC, HFRej, LFRej |
Pre-trigger Delay |
0 - 100% of memory size (adjustable in 1% increments or 100 ns) |
Post-trigger Delay |
0 - 10,000 divisions in real time mode, limited at slower time/div settings or in roll mode |
Hold-off |
From 2 ns up to 20 s or from 1 to 99,999,999 events |
Trigger and Interpolator Jitter |
≤ 3.5 ps RMS (typical) |
Internal Trigger Level Range |
±4.1 div from center (typical) |
External Trigger Level Range |
Ext (±0.4 V); Ext/10 (±4 V) |
Maximum Trigger Rate |
1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) |
Trigger Sensitivity with Edge Trigger (Ch 1–4) |
2 div @ < 1 GHz
1.5 div @ < 500 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling, ≥ 10 mV/div, 50 Ω) |
Trigger Sensitivity with Edge Trigger (External Input) |
2 div @ <1 GHz
1.5 div @ < 500 MHz
1 div @ < 200 MHz
0.9 div @ < 10 MHz
(DC, AC, and LFRej coupling) |
Max. Trigger Frequency, SMART Trigger |
1.0 GHz @ ≥ 10 mV/div (minimum triggerable width 750 ps) |
Basic Triggers |
Edge |
Triggers when signal meets slope (positive, negative, or either) and level condition |
Width |
Triggers on positive or negative glitches with selectable widths. |
Glitch |
Triggers on positive or negative glitches with selectable widths. Minimum width 200 ps, maximum width: 20 s |
Window |
Triggers when signal exits a window defined by adjustable thresholds |
Pattern |
Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern. |
TV-Composite Video |
Triggers NTSC or PAL with selectable line and field;
HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or
CUSTOM with selectable Fields (1–8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz),
Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative) |
Runt |
Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns. |
Slew Rate |
Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns. |
Interval |
Triggers on intervals selectable between 1 ns and 20 s. |
Dropout |
Triggers if signal drops out for longer than selected time between 1 ns and 20 s. |
Triggers with Exclusion Technology |
Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met |
Qualified (Timeout or State/Edge Qualified) |
Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. |
Low Speed Serial Protocol Trigger (Optional) |
I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553, AudioBus (I2S, LJ, RJ, TDM), USB1.x/2.0, SATA |
Measurement Tools |
Measurement Functionality |
Display up to 6 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Parameter gates define the location for measurement on the source waveform. |
Measurement Parameters - Horizontal + Jitter |
Delay (from trigger, 50%), Duty Cycle, Edges ,Fall Time (90-10, 80-20), Frequency, Period, Δ Period, Phase, Rise Time (10-90, 20-80), Skew, Width+, Width- |
Measurement Parameters - Vertical |
Amplitude, Base, Maximum, Mean, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top. |
Measurement Parameters - Pulse |
Area, Base, Fall Time (90-10, 80-20), Overshoot (positive, negative), Rise Time (10-90, 80-20), Top, Width+, Width- |
Math Tools |
Math Functionality |
Display up to 2 math functions traces (F1-F2). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math. |
Math Operators - Basic Math |
Average (summed), Average (continuous), Difference (–), Envelope, Exp (base e, base 10), Floor, Invert (negate), Log (base e, base 10), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+). |
Holdoff |
Holdoff between A and B, B and C, C and D is selectable by time (1ns to 20s) or number of events. Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage. |
Math Operators - Filters |
Enhanced resolution (to 11 bits vertical) |
Math Operators - Frequency Analysis |
FFT (power spectrum, magnitude), up to full record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows. |
Math Operators - Functions |
Absolute value, Derivative, Integral, Invert (negate), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity). |
Measurement and Math Integration |
|
Trend (datalog) of up to 1 million measurement parameters |
Pass/Fail Testing |
|
Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions) with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook. |
Display System |
Display Size |
Color 12.1” widescreen flat panel TFT-Active Matrix with high resolution touch screen |
Display Resolution |
WXGA; 1280 x 800 pixels |
Number of Traces |
Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces. |
Grid Styles |
Auto, Single,X-Y, Single+X-Y |
Waveform Representation |
Sample dots joined, or sample dots only |
Processor/CPU |
Type |
Intel® CoreTM i3-6100 Dual, 3.7 GHz (or better) |
Processor Memory |
8 GB standard |
Operating System |
Microsoft Windows® 7 For Embedded Systems 64Bits |
Oscilloscope Operating Software |
Teledyne LeCroy MAUI™ |
Real Time Clock |
Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks |
Connectivity |
Ethernet Port |
Supports 2 10/100/1000BaseT Ethernet interface (RJ45 ports) |
USB |
4 side USB 3.1 Gen1 ports, and 1 front USB 3.1 port support Windows compatible devices |
USB Device Port |
1 port - USBTMC over USB 3.1 Gen1 |
GPIB Port (optional) |
Supports IEEE – 488.2 (External) |
External Monitor Port |
DisplayPort 1.1 and HDMI to support customer-supplied external monitor. Includes support for extended desktop operation with UHD (3840 x 2160) pixel resolution and split-grid capability on external monitor. Supports touch screen integration of external monitor (Note: external display can not use a Fujitsu touch-screen driver). |
Remote Control |
Via Windows Automation, or via Teledyne LeCroy Remote Command Set |
Network Communication Standard |
VXI-11 or VICP, LXI Class C (v1.2) Compliant |
Probes |
Standard Probes |
Qty. (4) ÷10 Passive Probes |
Probing System |
ProBus. Automatically detects and supports a variety of compatible probes |
Power Requirements |
Voltage |
100-240 VAC ±10% at 50/60 Hz ±5%; 110-120 VAC ±10% at 400 Hz ±5%; Automatic AC Voltage Selection |
Power Consumption (Nominal) |
285 W / 285 VA |
Max Power Consumption |
375 W / 375 VA (with all PC peripherals and active probes connected to 4 channels) |
Environmental |
Temperature (Operating) |
+5 °C to +40 °C |
Temperature (Non-Operating) |
–20 °C to +60 °C |
Humidity (Operating) |
5% to 90% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C. |
Humidity (Non-Operating) |
5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F |
Altitude (Operating) |
Up to 10,000 ft. (3048 m) at or below +30 °C |
Altitude (Non-Operating) |
Up to 40,000 ft. (12,192 m) |
Random Vibration (Operating) |
0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Random Vibration (Non-Operating) |
2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Functional Shock |
30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total |
Physical Dimensions |
Dimensions (HWD) |
12.44”H x 16.42”W x 9.37”D (316 x 417 x 238 mm) |
Weight |
22.8 lbs. (10.3 kg) |
Certifications |
|
CE Compliant, UL and cUL listed; conforms to UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition) CAN/CSA C22.2 No. 61010-1-12 |
Warranty and Service |
|
3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services. |