| ENET |
| Definition |
| Protocol Setup |
Selection for source channels. Supports Single (differential probe) or dual (two single-ended probes) input(s) for decoder. Detects auto negotiation (option for 100BASE-TX). |
| Decode Capability |
| Format |
Ethernet 10BASE-T and 100BASE-TX Protocol Decode (Hexadecimal). |
| Decode Setup |
Selection for source inputs. |
| Decode Input |
Any analog Channel, Memory or Math trace. |
| # of Decode Waveforms |
Up to 4 unique lanes may be decoded at one time. In addition, zooms can be displayed (with decoded information). |
| Location |
Overlaid over waveform, on Grid |
| Visual Aid |
Color Coding for Frame, Group Primitives, Data words, Primitive words, and important frame fields such as address and Ethernet type. Decode information is intelligently annotated based on timebase setting. |
| Search Capability |
| Pattern Search |
Search by the following: Any, Frame, Idle, Source Address, Destination Address, FLP Burst, Electrical Idle, Protocol Errors: Any, Missed Terminate, Missed Start of Frame, Frame Length Error, Preamble Value Error, Start of Frame, Delimiter Value Error, CRC Error, Data Size Error |
| Other |
| Compatible With... |
Fully compatible with HDO6000, HDO4000, WaveSurfer® Xs/Xs-A/Xs-B Series, WaveRunner® 6 Zi Series, WaveRunner® Xi/Xi-A Series, WavePro® 7 Zi/Zi-A Series, WaveMaster® 8 Zi/Zi-A Series, LabMaster 9Zi-A Series, and LabMaster 10Zi Series. Bandwidth of oscilloscope must be equal to bit rate with a minimum oscilloscope sample rate of 4x the bit rate. |