Keysight N9915CU/330 - Pulse Measurements with USB Peak Power Sensor Option for N9915C
REQUIRES OPTION 302 – SOLD SEPARATELY. POWER SENSOR SOLD SEPARATELY
Option 330 is the Pulse Measurement option for FieldFox analyzers.
FieldFox’s pulse measurement option can be used to characterize RF pulses such as those used in radar and electronic warfare systems. Measurements are made using FieldFox and Keysight’s USB peak power sensors.
Performance specifications such as frequency, dynamic range and minimum pulse width depend on the peak power sensor.
- Setup parameters
- Frequency, time (center), time/division, gating, triggering, video bandwidth, averaging
- Functions
- Average power, peak power, and peak to average ratio
- Analog gauge display and digital display, dBm and Watts
- Relative/absolute measurements, offset, dB or %, minimum and maximum limits
- Trace graph for pulse profiling with gating
- Rise time, fall time, pulse width, pulse period, pulse repetition frequency