Keysight D9010ETHC - 10M/100M/1GBASE-T and Energy Efficient Ethernet Compliance Test Application Software; Perpetual License
This software requires the following for full functionality:
- Keysight D9010SCNA - InfiniiScan Event Identification Software
- Keysight D901OJITA - EZJIT Complete - Jitter and Vertical Noise Analysis Software
This item is a perpetual license for the D9010ETHC software package. Support options for this package are listed in the accessories section of this page.
Types of perpetual licenses
There are five variations of the perpetual license listed in the menu above – they are as follows:
- Floating
- Networked instruments/computers can access a license from a server one at a time. Multiple licenses may be purchased for concurrent usage.
- Single site: 1-mile radius from the server
- Single region: North, Central, and South America, Canada
- Node locked
- The license can be used on one specified instrument/computer
- Transportable
- The license can be used on one instrument/computer at a time but may be transferred to another using Keysight Software Manager (internet connection required)
- USB Portable
- The license can be used on one instrument/computer at a time but can be transferred to another using a certified USB dongle (available for additional purchase, Keysight part number E8900-D10)
D9010ETHC Information
The Keysight compliance test application provides a fast and effortless way to test, debug and characterize your 10M/100M/1GBASE-T Ethernet designs. The Keysight D9010ETHC 10M/100M/1GBASE-T compliance application software for Infiniium real-time oscilloscopes saves time and money by automating the task of performing compliance measurements. The tests performed by the D9010EBSC software are based on the IEEE 802.3-2005 and ANSI X3.263-1995 standards specification and for Energy Efficient Ethernet the IEEE802.3az-2010 standard. The test application offers a user-friendly setup wizard and a comprehensive report that includes margin analysis.
To make 1000BASE-T, 100BASE-TX and 10BASE-T measurements with the D9010ETHC 10M/100M/1GBASE-T and Energy Efficient Ethernet compliance application software, the Keysight N5395C Ethernet electrical conformance test fixture is needed. For Energy Efficient Ethernet compliance testing, order the Wilder Technologies Energy Efficient Ethernet fixture (P/N: EEE-TPAERK). To make 1000BASE-T jitter measurements, the Keysight N5396A Gigabit Ethernet jitter test cable is also needed. In addition, the user can use a wide variety of Keysight waveform generators, including the Keysight 33612A as a disturbing signal source and choose from a variety of Keysight vector network analyzers such as the E5080A ENA vector network analyzer to make return loss measurements. Performing these tests gives the user confidence in their design. The D9010ETHC 10M/100M/1GBASE-T and Energy Efficient Ethernet compliance application software helps execute a wide subset of the conformance tests that can be measured with an oscilloscope.
D9010ETHC Software Highlights
- Comprehensive Measurement and Debug Solution
Rapid and automated compliance testing of Energy Efficient Ethernet network devices to the IEEE 802.3az-2010 specification
Rapid and automated compliance testing of Energy Efficient Ethernet network devices to the IEEE 802.3az-2010 specification
- Flexible and Extensible
The automated setup ensures result repeatability and lets test engineers run the application without being an expert on Energy Efficient Ethernet testing procedures.
Test setup wizard guides user through test selection, configuration, connection, execution and results reporting.
The oscilloscope setup is automatically configured for each test, and measurement connection setups are displayed.
Test results report test configuration, measurements made, pass/fail status, margin analysis and waveforms.
Oscilloscope Compatibility
The Keysight D9010ETHC 10M/100M/1GBASE-T and Energy Efficient Ethernet compliance test application software is compatible with Keysight Infiniium Series oscilloscopes with operating software revision 6.30 or higher.