| Display |
| |
A perfect view
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C) |
| |
Additional plain text information
Comfortable LCD dialog display for interactive operation with plain text display |
| |
Pump stage and liquid level
A Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT |
| Operation |
| |
Comfortable and detailed
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc. |
| Temperature Control |
| |
For perfect results
‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external |
| |
Full control
‘Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc. |
| |
Highest measuring accuracy
‘Absolute Temperature Calibration’ for manual compensation of a temperature |
| Refrigeration Technology |
| |
Energy saving cooling
Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated cooling machines |
| |
Consistent cooling capacity
Easily removable venting grid for quick and easy cleaning |
| |
100 % Cooling capacity
'Active Cooling Control' for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures |
| |
Condensation and ice protection
A heated cover plate prevents condensation or ice build-up in the bath |
| |
For flammable bath fluids
Classification III (FL) according to DIN 12876-1 |
| Technical Features |
| |
Clever pump system
Reliable and consistent pump capacity, electronically adjustable pump stages |
| |
Control from the external application
External Pt100 sensor connection for precise measurement and control directly in the external application |
| |
Serial connection
RS232 interface for PC connection, e.g. for data communication and recording of measured values |
| |
Optimal program control
For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock |
| |
Connection of additional equipment
Stakei connections for solenoid valve, HSP booster pump and HST booster heater |
| Warning & Safety Functions |
| |
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down |
| |
Early warning system for high/low temperature limits
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function |
| |
Enhanced protective functions
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments |