Model | GDS-820 | GDS-820S | GDS-820C | GDS-840S | GDS-840C |
Display System |
Display Device | Mono (320*240) 5.7" LCD | Mono (320*240) 5.7" LCD | Color (320*240) 5.7" LCD | Mono (320*240) 5.7" LCD | Color (320*240) 5.7" LCD |
Display Contrast | Adjustable |
Waveform Display Graticule | 8 x 10 division |
Display Mode | Dot, Vector, Accumulate |
Vertical System |
Bandwidth | DC~150MHz | DC~250MHz |
Channels | 2 |
Resolution | 8-Bit |
Sensitivity | 2mV/div to 5V/div |
Accuracy | ±3? |
Rise Time | <2.3ns | <1.4ns |
Input Coupling | AC, DC & Ground |
Input Impedance | 1MΩ ±2Ω, ~22pF |
Polarity | Normal & Invert |
Maximum Voltage Between Signal and Common at input BNC | 300V (DC+AC peak), CATII |
Waveform Signal Process | CH1-CH2, CH1+CH2, FFT |
Offset Range | 2mV/div ~ 50mV/div: ±0.5V ; 100mV/div ~ 500mV/div: ±5V ; 1V/div ~ 5V/div: ±50V |
Bandwidth Limit | 20MHz (-3dB) |
Horizontal System |
Range | 1ns/div ~ 10s/div (1-2-5 increments) |
Modes | MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y |
Accuracy | ±0.01? |
Delay Range | Pre-trigger: 10 div maximum ; Post-trigger: 500 div |
Signal Acquisition System |
Real-time Sample Rate | 100MSa/s maximum on each channel |
Equivalent Sample Rate | 25GSa/s maximum on each channel |
Record Length | 125k/CH |
Peak Detection | 10ns (10μs/div ~ 5s/div) |
Acquisition Mode | Sample, Peak Detect, Average |
Average | 2, 4, 8, 16, 32, 64, 128, 256 |
Trigger System |
Sources | CH1, CH2, LINE, EXT. |
Modes | Auto-Level,AUTO,NORMAL,SINGLE,TV,Time-delay,Event-delay |
Coupling | AC, DC, LF Reject, HF Reject, Noise Reject |
Sensitivity | DC ~ 25MHz: Approx. 0.35div or 3.5mV 25MHz ~ 100MH : Approx. 1.5div or 10mV | DC ~ 25MHz: Approx. 0.35div or 3.5mV |
25MHz ~ 250MHz | Approx. 1.5div or 10mV |
External Trigger |
Range | ±15V |
Sensitivity | DC ~ 30MHz: ~ 50mV 30MHz ~ 100MHz: ~ 100mV | DC ~ 30MHz: ~ 50mV 30MHz ~ 100MHz: ~ 100mV 150MHz ~ 250MHz: ~ 150mV |
Input Impedance | 1MΩ ±2Ω, ~ 22pF |
Maximum Input | 300V (DC+AC peak), CATII |
X-Y Mode |
X-Axis Input / Y-Axis Input | Channel 1 / Channel 2 |
Phase shift | ±3°at 100kHz |
Cursors and Measurement |
Automated Voltage Measurement | Vpp,Vamp,Vavg,Vrms,Vhi,Vlo,Vmax,Vmin |
Automated Time Measurement | Freq, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
Cursors Measurement | Voltage difference between cursors (?V) Time difference between cursors (?T) Frequency difference between cursors (1/?T) |
Frequency Counter |
Readout Resolution | 6 digits |
Accuracy | ±50ppm |
Range | AC Coupled, 10Hz minimum to rated bandwidth |
Signal Source | All available trigger source except the Pulse Width & Video Trigger mode |
Control Panel Functions |
Autoset | "Autoset" can adjust Vertical, Horizontal and Trigger level automatically |
Save/Recall | Up to 15 sets of measurement conditions can be saved and recalled |
Waveform Trace Save/Recall | 2 sets of waveform can be saved and recalled |
Interface |
RS-232 Interface | N/A | Standard |
GPIB Interface | N/A | Option |
Printer Port | N/A | Standard |
USB Port | N/A | Standard |
Misc |
Power Source | 100V ~ 240V AC 48Hz ~ 63Hz, auto selection |
Accessories | Instruction manual x 1, Power cord x 1, Probe x 2 |
Dimensions & Weight | 254D?142H?310W (mm), Approx. 4.1kg |