MEASUREMENT CHARACTERISTICS |
INPUT |
ITEM |
|
Range |
RATING VOLTAGE |
|
600 Vrms |
RATING CURRENT |
|
20 Arms |
IMPEDANCE(50/60Hz) |
Voltage |
2.4 MΩ |
Current |
5mA~200mA: 500 mΩ |
Current |
0.5A~20A: 5 mΩ |
MAXIMUM VOLTAGE |
|
700 Vrms |
MAXIMUM CURRENT |
|
25 Arms |
MAXIMUM COMMON |
|
300 V |
LOW PASS FILTER |
Cutoff frequency |
500 Hz |
PARAMETERS |
ITEM |
|
Symbol |
MEASUREMENT |
Voltage |
Vdc, Vrms, V+pk, V-pk |
Current |
Idc, Irms, I+pk, I-pk |
Power |
P, P+pk, P-pk, VA, Var |
Crest Factor |
CFV, CFI |
Power Factor |
PF |
Frequency |
VHz, IHz |
Angle |
Deg |
Total Harmonic Distortion |
THDV, THDI |
Integration |
Time, WP, WP+, WP-, q, q+, q- |
DISPLAY DIGITS |
|
5 digits |
FREQUENCY BANDWIDTH |
|
DC, 45Hz~6kHz |
AVERAGE |
|
1, 2, 4, 8, 16, 32, 64 |
PT RATE |
|
1 ~ 9999.999 |
CT RATE |
|
1 ~ 9999.999 |
DISPLAY MODE |
Standard |
8 measurement Item |
|
Simple |
4 measurement Item |
VOLTAGE |
ITEM |
|
Range |
RANGE |
CF=3 |
15V, 30V, 60V, 150V, 300V, 600V |
CF=6 |
7.5V, 15V, 30V, 75V, 150V, 300V |
CREST FACTOR |
|
3 or 6 (selectable) |
ACCURACY |
Effective Range |
1% ~ 105% of range |
|
DC |
±(0.2% of reading+0.2% of range) |
|
45Hz ≤ f ≤66Hz |
±(0.1% of reading+0.1% of range) |
|
66Hz < f ≤1kHz |
±(0.1% of reading+0.2% of range) |
|
1kHz < f ≤6kHz |
±3% of reading |
|
Filter (ON) |
Add 0.3% of reading@45Hz ~ 66Hz |
TEMPERATURE EFFECT |
5-18゚C / 28-40゚C |
Add ±0.03% of reading/゚C |
RESIDUAL NOISE |
|
0.5% of range |
CURRENT |
ITEM |
|
Range |
MEASUREMENT |
CF=3 |
5mA, 10mA, 20mA, 50mA, 100mA, 200mA, 1A, 2A, 5A, 10A, 20A |
CF=6 |
2.5mA, 5mA, 10mA, 25mA, 50mA, 100mA, 0.5A, 1A, 2.5A, 5A, 10A |
CREST FACTOR |
|
3 or 6 (selectable) |
ACCURACY |
Effective Range |
1% ~ 105% of range |
DC |
±(0.2% of reading+0.2% of range) |
45Hz ≤ f ≤66Hz |
±(0.1% of reading+0.1% of range) |
66Hz < f ≤1kHz |
±(0.1% of reading+0.2% of range) |
1kHz < f ≤6kHz |
±3% of reading |
Filter (ON) |
Add 0.3% of reading@45Hz ~ 66Hz |
TEMPERATURE EFFECT |
5-18゚C/28-40゚C |
Add ±0.03% of reading/゚C |
RESIDUAL NOISE |
|
0.5% of range |
POWER |
ITEM |
|
Range |
Measurement |
Filter (ON) |
30.000 Hz~9.9999 kHz |
Filter (OFF) |
30.000 Hz~499.99 Hz |
Parameter |
|
Voltage, Current |
Effective Range |
|
10%~105% of voltage input |
Accuracy |
|
±0.06% of reading |
FREQUENCY |
ITEM |
|
Range |
Measurement |
Filter (ON) |
30.000 Hz~9.9999 kHz |
Filter (OFF) |
30.000 Hz~499.99 Hz |
Parameter |
|
Voltage, Current |
Effective Range |
|
10%~105% of voltage input |
Accuracy |
|
±0.06% of reading |
|
|
|
INTEGRATION |
ITEM |
|
Range |
INTERGRATION |
Accuracy |
±(voltage or current accuracy+0.1% of reading) |
TIME |
Range |
0 hour 00 min ~ 9999 hour 59 min |
Accuracy |
±0.01%±1second |
GENERAL INFORMATION |
DISPLAY |
4” TFT LCD |
STANDARD INTERFACE |
RS-232C, USB device, LAN |
POWER SOURCE |
AC 100~240 V, 50-60Hz |
POWER CONSUMPTION |
Max. 25VA |
DIMENSION & WEIGHT |
270(W) x 110(H) x 350(D) mm, Aapprox. 2.9kg |