Application |
Fitted in a 3193 unit (factory-fitted option) |
Measurement lines |
Single-phase,two-wire (1P2W)/ Single-phase,three-wire (1P3W)/ Threephase, three-wire (3V3A, 3P3W)/ Three-phase,four-wire (3P4W) |
Number of channels |
Maximum of 3 channels selectable from channels 1 to 6, depending on 3193 unit wiring mode
|
1ch |
2ch |
3ch |
4ch |
5ch |
6ch |
Using Channels |
1 |
1P2W |
1P2W |
1P2W |
1P2W |
1P2W |
1P2W |
1+2+3, 2+3+4, 3+4+5, 4+5+6 |
2 |
1P3W/3P3W |
1P2W |
1P2W |
1P2W |
1P2W |
12+3, 3+4+5, 4+5+6 |
3 |
1P3W/3P3W |
1P3W/3P3W |
1P2W |
1P2W |
12+3, 34+5, 4+5+6 |
4 |
1P3W/3P3W |
1P3W/3P3W |
1P3W/3P3W |
12+3, 34+5, 56 |
5 |
3V3A/3P4W |
1P2W |
1P2W |
1P2W |
123, 4+5+6 |
6 |
3V3A/3P4W |
1P3W/3P3W |
1P2W |
123, 45+6 |
7 |
3V3A/3P4W |
3V3A/3P4W |
123, 456 |
|
Measurement range |
Basic frequency 1 to 440 Hz, external clock type: 1 to 5 Hz, PLL type: 5 to 440 Hz
For fundamental from 45 Hz to 66 Hz, measurement is compliant with IEC61000-3-2 and MITI guidelines (constant measurement / fluctuating measurement), except no 2.5-minute fluctuating measurement or waveform decision function. |
Measurement system |
PLL synchronization
For fundamental from 45 Hz to 66 Hz, fundamental frequency and PLL synchronizing frequency phase deviation no more than 0.01% |
Analysis method |
FFT |
Type of window |
Rectangular (no gaps or overlaps in window) |
Display update rate |
Every 1 window (excluding when FFD/printer output and communication) |
A/D |
16 bits |
Computational accuracy |
32 bits (floating-point calculations) |
PLL source |
Select voltage (U) or current (I) from the channel combination selected for measurement |
External clock signal |
Input clock signal of frequency ((measured signal frequency) 8192 256) (TTL levels) enables measurement in the low-frequency range (1 Hz to 5 Hz) |
Crest factor |
4 max. (current), 3 max. (voltage) |
Output function |
FD, printer,GP-IB, RS-232C |
Sampling rate |
External clock input frequency: (1 to 5 Hz) 8192 256
Analysis harmonic order: 50th
Window width: 1 cycle
Basic input frequency |
Sampling rate |
Analysis harmonic order |
Window width |
5 to 10 Hz |
f×4096 |
50th |
2 cycles |
10 to 20 Hz |
f×2048 |
50th |
4 cycles |
20 to 40 Hz |
f×1024 |
50th |
8 cycles |
40 to 70 Hz |
f×512 |
50th |
16 cycles |
70 to 140 Hz |
f×256 |
50th |
32 cycles |
140 to 250 Hz |
f×128 |
50th |
64 cycles |
250 to 440 Hz |
f×64 |
27th |
128 cycles |
|