Display |
LCD, 16 characters × 2 lines, 5 × 8 dots / characters |
Input System/Channels |
Analog inputs: 10 (M3 mm dia. screw terminal block), electrically isolated between channels, and from chassis ground.
Input impedance: 2MO (when voltage input or temperature measuring with thermocouple burn-out detection OFF), 850 kO (with thermocouple burn-out detection ON)
Pulse inputs: 4 channels (requires HIOKI Input Cable 9641)
Note: all pulse inputs share common ground with the HiLOGGER |
Analog Inputs |
Maximum rating: 60 V DC (max. voltage between input terminals without damage),
Maximum rated voltage from isolated terminals to ground: 60 V DC (max. voltage between input channel terminals, and from terminals to chassis ground without damage) |
Pulse Inputs |
Input limits: -5 to +10 V DC (max. voltage between input terminals without damage), non-isolated (common ground between pulse input channels, and with chassis)
Pulse signal characteristic: no-voltage relay contact “a”, open collector or voltage input (High: = 2.5 V, Low: = 0.9 V), Period: at least 200 µs (both high and low periods at least 100 µs) |
Alarm Output |
One channel, non-isolated: output from external control connector (common ground)
Signal criteria: configurable high/low threshold levels, enter/ exit threshold window, logical sum (OR) and logical product (AND) for every input channel. Output is refreshed each time recording starts.
Signal characteristic: Open-collector output (active low, with voltage output) Voltage levels: 4.0 to 5.0 V (H) and 0 to 0.5 V (L),
Max. sink current: 5 mA DC, Max. applied voltage: 30 V DC |
Data Recording Capacity |
Internal storage: 3.5 MWords (7 MB of two-byte data points, or fourbyte pulse measurements)
External storage: Up to 1 GB (HIOKI CF cards only) |
Real-Time Data Saving |
Waveforms are saved in real time as binary data to the CF card, and can be saved to separate files at preset times. Overwriting saving is available. Stored data can be recalled by the HiLOGGER in 3.5 MWord (7MB) quantities (for a single channel; less for multiple channels) |
Backup Function(@25°C) |
Backup battery life for clock and settings: approx. 5 years For measurement data: 100 hours with fully charged battery pack, or for as long as AC adapter is connected |
External Control Terminals |
External Trigger/Event Mark input (exclusion function), Trigger Output, Alarm Output |
External Interface |
One USB 2.0 series B receptacle (transfers internal data to and control signals from a PC) |
Environmental conditions (no condensation) |
Temperature and humidity range for use: 0°C to 40°C (32°F to 104°F), (or 5°C to 30°C, 41°F to 86°F when battery charging) 30 to 80% rh or less
Temperature and humidity range for storage: -10°C to 50°C (14°F to 122°F), 80% rh or less |
Compliance standard |
Safety: EN61010, EMC: EN61326, EN61000 |
Power Sources |
1) 100 to 240 V AC, 50/60 Hz using AC Adapter Model 9786
(2) Battery Pack Model 9780 (when used with the AC Adapter, the AC Adapter has priority)
(3) 12 V battery (10 to 16 V DC ±10%, Please contact HIOKI for connection cord) |
Power Consumption |
10 VA (using 12 V battery, while charging Battery Pack 9780)
30 VA (using AC Adapter, while charging Battery Pack 9780) |
Continuous Operating Time |
Approx. 2.5 hours (with Battery Pack Model 9780)
Charging time: Approx. 200 minutes (@5°C to 30°C ambient) |
Dimensions and mass |
Approx. 176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61in) D, 550 g (19.4 oz) (HiLOGGER only) |
Supplied Accessories |
Instruction Manual × 1, Measurement Guide × 1, Application Disk (Logger Utility program) × 1, USB cable × 1, AC Adapter 9786 × 1, Shoulder Strap × 1, Protection Sheet 9809 × 1 |