Display |
LCD, 16 characters × 2 lines, 5 × 8 dots / characters |
Memory capacity |
Total 16 M-word (about 16.77 million data points: 32 mega-bytes) |
External control connectors |
Push-button type terminal block : External trigger/ External sampling input (exclusive OR), External start input, External stop input
External sampling : rise-up, or fall-down (selectable)
Rise-up : Low (0 to 1.0 V) to High (2.5 to 5.0 V)
Fall-down : High (2.5 to 5.0 V) to Low (0 to 1.0 V), or terminal short
Input voltage range : -5 to 10 V DC, Filter ON/OFF possible
Pulse width response : Over 1 ms at "H", over 2 µs at "L" (at fi lter OFF), Over 2.5 ms at "H", over 4 ms at "L" (at fi lter ON)
Maximum external sampling period : 10 ms (at digital fi lter OFF), 20 ms (at digital fi lter OFF, and synchronous measurement), 5 s (at digital fi lter ON, and combined with humidity measurement)
Synchronous sampling : Five-units maximum for synchronous connection, Function : Connect via the connection cable model 9683 for synchronous sampling |
Clock |
Auto calendar, leap year auto distinguish, Precision : ±0.2s/ day at power ON, ±3s/ day at power OFF (at 23 °C/ 73°F) |
Accuracy of timebase |
±0.2s/ day on measurement (at 23 °C/ 73°F) |
Recording intervals |
10ms, 20ms, 50ms, 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min, 10min, 20min, 30min, 1hr (5s to 1hr when combined with humidity measurement) |
Recording length |
Set to arbitrary length or continuous; Data storage : last 16-mega datas in internal memory (for one channel recording. For n channels, 16 M-datas / n data) |
Recording mode |
Continue, Repeat, Timer measurement |
Number of data |
For analog "n" channels, ( 16-mega datas / n ) datas |
Durability of battery |
Backup battery for clock and setting conditions: battery life of at least 10 years, For measurement data: none (at 23 °C/ 73°F) |
No. of connectable units |
Maximum 8 units (total 120 channels) |
Environmental conditions |
Operating temperature and humidity : 0 (32°F) to 40°C (104°F), 30 to 80% rh, Storage temperature and humidity : -10 (14°F) to 50°C (122°F), 80% rh or less, (non-condensating) |
Conforming standards |
Safety : EN61010, EMC : EN61326, EN61000-3-2, EN61000-3-3 |
Power supply |
(1) Using the AC ADAPTER 9418-15, 100 to 240 VAC, 50/60 Hz (2) 12 V Battery (voltage may range from -20% to +30%, Please contact HIOKI for connection cord). |
Power consumption |
20 VA (when connected with 8 units) |
Dimensions & Mass |
Approx. 67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) |
Accessories |
Operating Manual ×1, Quick Start Manual ×1, AC ADAPTER 9418-15 ×1, USB cable ×1, Connection Plate ×1, CD-R (data collection software "Logger Utility") ×1, Connector cover ×1, Ferrite clamp ×1 |