Specifications (Accuracy guaranteed for 1 year; Post-adjustment accuracy guaranteed for 1 year) |
Accuracy
Accuracy is guaranteed with a laser light source. Accuracy is not guaranteed with standard illuminant A (light bulb). |
Accuracy guarantee temperature and humidity range |
Temperature: 23°C ±5°C (73°F ±9°F), Humidity: 80% RH or less (Warm-up: 30 minutes or longer) |
Radiometric quantity |
Relative accuracy |
±4.6% rdg. (473 nm, 40 μW)
Standard (532 nm, 60 μW)
±4.6% rdg. (633 nm, 80 μW) |
±4.6% rdg. (473 nm, 40 μW)
Standard (532 nm, 60 μW)
±4.6% rdg. (633 nm, 80 μW) |
- - - |
Accuracy |
±6.5% rdg. (532 nm, 9 mW/m2) |
±8% rdg. (532 nm, 3 W/sr m2) |
±4.2% rdg. (473 nm, 0.1 mW)
±4.2% rdg. (532 nm, 0.1 mW)
±4.2% rdg. (632.8 nm, 0.1 mW) |
Centroid wavelength |
Blue |
±0.5 nm (435.8 nm mercury lamp) |
Green |
±0.5 nm (546.1 nm mercury lamp) |
Red |
±0.5 nm (632.8 nm, 0.1 mW) |
Basic Specifications |
Radiometric quantity |
Measurement parameter |
Irradiance |
Radiance |
Radiant flux (Optical power) |
Measurement range |
0.0002 to 200 [W/m2] |
0.002 to 600 [W/sr m2] |
0.00001 to 130 [mW] |
Centroid wavelength measurement range |
Blue |
435 nm to 477 nm |
Green |
505 nm to 550 nm |
Red |
615 nm to 665 nm |
Photometric quantity |
Measurement parameter |
Illuminance |
Luminance |
Luminous flux |
Measurement range |
0.2 to 110 000 [lx] |
2 to 300 000 [cd/m2] |
10 μlm to 60 lm |
Specified conditions |
Centroid wavelength: 473 nm, 532 nm, 632.8 nm/RGB radiometric quantity output ratio: Ratio based on D65 chromaticity If the radiometric quantity is less than 10% of the range full scale, use of centroid wavelength input mode (fixed) is recommended. |
Measured field diameter |
- - - |
Close contact: Approx. φ12 mm (0.47 in)
5 mm (0.20 in): Approx. φ14 mm (0.55 in)
10 mm (0.39 in): Approx. φ16 mm (0.63 in) |
- - - |
Measured field angle |
- - - |
Approx. 22° *1 |
- - - |
Oblique incident light properties |
Cosine law approximation |
- - - |
- - - |
Light receiving diameter |
φ11.3 mm ±0.1 mm (0.44 in ±0.0039 in) |
- - - |
φ11.3 mm ±0.1 mm (0.44 in ±0.0039 in) |
Measurement time |
15 ms to 460 ms |
Correction function |
Centroid wavelength input mode, centroid wavelength offset, radiometric quantity gain, chromaticity value xy offset, photometric quantity gain |
Dark measurement |
Judgment of dark measurement result, averaging, dark estimation |
Other Measurement parameters |
Tristimulus values XYZ, chromaticity (xy, u'v'), correlated color temperature, Delta uv, dominant wavelength, NTSC ratio, white balance target value of radiometric quantity |
White balance adjustment support functions |
Parameters: Target value of photometric quantity, tolerance of photometric quantity, target value of chromaticity (x, y), tolerance of chromaticity (x, y) |
Modulated light function |
Modulation frequency setting range: 10 Hz to 300 Hz, Modulation frequency measurement range: 10 Hz to 300 Hz |
Interface |
LAN (TCP/IP) * A display is not available on the unit. |
Dimensions |
65 mm (2.56 in) W × 83 mm (3.27 in) H × 126 mm (4.96 in) D |
65 mm (2.56 in) W × 83 mm (3.27 in) H × 175.7 mm (6.92 in) D |
65 mm (2.56 in) W × 83 mm (3.27 in) H × 135.5 mm (5.33 in) D |
Mass |
700 g (24.7 oz) |
790 g (27.9 oz) |
720 g (25.4 oz) |
Compliance standards |
Safety EN61010 / EMC EN61326 |
Power supply |
AC ADAPTER: Z1008 (100 V AC to 240 V AC, 9.5 VA) |
*1 When measuring directional light sources, please note that the difference in measurement field angles will affect radiance. |