Measurement system |
Two-electrode method/three-electrode method (switchable) |
Measurement range |
20 Ω (0 Ω〜20.00 Ω) |
200 Ω (0 Ω〜200.0 Ω) |
2000 Ω (0 Ω〜2000 Ω) |
Accuracy |
±1.5% rdg ±8 dgt |
±1.5% rdg ±4 dgt |
±1.5% rdg ±4 dgt |
Earth voltage |
0〜30.0 V rms
Accuracy: ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC) |
Allowable earth potential |
25.0 V rms (DC or sine wave) |
Dustproof and waterproof |
IP65/IP67 (EN60529) |
Power supply |
LR6 Alkaline battery ×4, Possible number of measurements: 500 times (measurement conditions: three-electrode method, measuring 10 Ω at 10-second intervals without Z3210 installed) |
Functions |
Live wire warning, zero-adjustment, continuous measurement mode, wireless communication (only when Z3210 is connected), and comparator |
Dimensions and mass |
185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D, 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories) |
Operating environment |
Indoors, pollution degree 2, operable at an altitude specified in specifications of each measuring instrument to which the adapter is attached |
Operating temperature and humidity (Storage temperature and humidity) |
-30℃ (-22℉) to 70℃ (158℉), 90% RH or less (no condensation) |
Standards |
Safety: EN61010
RF: EN300 328
RF EMC: EN301 489-1, EN301 489-17
Exposure: EN62479 |
Maximum attaching/detaching count |
5000 times |
GENNECT Cross App confirmed compatible OSs |
iOS 13 or later, Android 8 or later, Bluetooth® 4.0 or later |
Bluetooth® communication distance |
About 10 m (line-of-sight distance) |
Product warranty period |
3 years (do not exceed the maximum attaching/detaching count) |
Dimensions and mass |
Approx. 16.4 mm (0.65in)W × 6.7 mm (0.26in)H × 15.6 mm (0.61in)D, 1.5 g (0.05 oz.) |