AC measurement method |
CM3281: MEAN Value
CM3291: True RMS |
Core jaw diameter |
Φ 46 mm (1.81 in), jaw thickness: 8.3 mm (0.33 in) |
Max. rated voltage to earth |
Jaw: CAT IV 300 V, CAT III 600 V
Voltage measurement terminal: CAT III 300 V, CAT II 600 V |
AC current |
42.00 A/ 420.0 A/ 2000 A (±1.5% rdg.±5 dgt.) |
Frequency characteristics |
CM3281: 50 Hz to 60 Hz
CM3291: 40 Hz to 1 kHz |
AC voltage |
4.200 V to 600 V, 4 ranges (±1.8% rdg.±7 dgt.) |
Frequency characteristics |
45 Hz to 500 Hz |
DC voltage |
420.0 mV to 600 V, 5 ranges (±1.0% rdg.±3 dgt.) |
Resistance |
420.0 Ω to 42.00 MΩ, 6 ranges (±2.0% rdg.±4 dgt.) |
Continuity check |
420.0 Ω (±2.0% rdg.±4 dgt.)
Threshold of buzzer sound 50 Ω ±40 Ω or less |
Crest factor (Only for CM3291) |
2.5 at 2500 count or less (linearity reduced to 1.5 or
less at 4200 counts), (1.5 or less at 2000 A range) |
Display refresh rate |
400 ms |
Operating temperature and humidity |
-25°C to 65°C (-13°F to 149°F), 80% RH or less (no condensation) |
Storage temperature and humidity |
-25°C to 65°C (-13°F to 149°F), 80% RH or less (no condensation) |
Drop-proof distance |
1 m (3.28 ft) onto concrete |
Standards |
Safety: EN 61010, EMC: EN 61326 |
Functions |
Data hold, Auto power-saving function |
Power supply |
Coin type lithium battery CR2032 × 1 |
Continuous use |
CM3281: 120 hours, CM3291: 70 hours |
Dimensions and mass |
57 mm (2.24 in)W × 197.5 mm (7.78 in)H × 16 mm
(0.63 in)D, 100 g (3.5 oz) |
Accessories |
Carrying Case, Test Lead L9208, Coin type lithium battery
CR2032, Instruction Manual, Operating Precautions |