Hart Scientific 9933 Software / Licenses / Software Maintenance

0 reviews | Model: Hart Scientific 9933


SOFTWARE, TABLEWARE

  • Hart's TableWare software is a stand-alone coefficient calculation and table generation package.
  • Shared File Conflict - Prior to this version, the Shared Files Conflict dialog always appeared when running the software in Windows NT with the file COMMDLG.DLL listed. Even though the software works fine despite this file conflict, this problem has been fixed.
  • Type R and S Extrapolation - A new range setting has been added for Type R and Type S Thermocouple probes. This range is named "-50.0°C to 1768.1°C (using extrapolation)". Selecting this range allows Generate-it to automatically determine which reference function to use when calculating coefficients and table values based on the temperature value. Selecting one of the other available ranges forces TableWare to use only the reference function for that range.
  • Temperature vs. EMF (mV) - Temperature vs. EMF (mV) tables can now be generated as well as Temperature vs. EMF (uV) for thermocouple probes.
  • Residuals Scale - Residuals for thermocouple probes are now displayed/printed in the scale that the UUT readings were entered in instead of always being displayed/printed in uV.
  • Overflow error - In TableWare version 2.2, an Overflow error sometimes occured when attempting to generate tables from thermistor polynomial coefficients that TableWare calculated. This problem has been fixed.
  • Temperature vs. EMF tables - Prior to version 2.3, there was an error generating Temperature vs. EMF tables for thermocouple probes: the calculated deviation coefficients were not being applied to the standard coefficients causing the Error column on the table to always display an error of 0.0 at every point. This bug has been fixed.
  • Thermistor Polynomials - The maximum order for thermistor polynomials has been reduced from 9th order to 6th order. Thermistor probes do not need to be fitted above the 6th order.
  • Inverse Difference - When generating Temperature vs. Ratio tables, the Inverse Difference column was incorrectly labeled "dT/dr". The label has been changed to correctly read "dT/dW".
  • Export raw data - An Export button has been added to the Raw Data dialog which allows raw data to be saved to an ASCII text file in comma delimited format.
  • Calculates coefficients for RTDs, thermistors and thermocouples
  • Generates three types of temperature tables
  • Easy-to-use, time-saving interface
  • Outputs to ASCII text file or printed report
  • We ship Hart Scientific products only within the United States and United States territories. This DOES include US military working abroad. If you have any questions about this policy please call - 1-877-742-8378.