| ELECTRICAL SYSTEMS |
Single Phase, 3 Phase without Neutral, 3 Phase with Neutral |
| CHANNELS RECORDED SIMULTANEOUSLY |
Phase to Neutral and Phase to Phase voltages, Phase currents, THD% voltages and currents, Phase and total active and reactive power, Phase and total power factor and Cosφ, Phase and total active and reactive energy |
| CHANNELS RECORDED SIMULTANEOUSLY |
| Integration Period |
5, 10, 30s, 1, 2, 5, 10, 15, 60min. |
| Recording autonomy |
> 230 days with integrated period of 15 minutes |
| Memory capacity |
8Mbyte |
| POWER SUPPLY |
| Internal power supply |
Rechargeable battery, battery life approx. 1 hour |
| External power supply |
By mean Red/Yellow plugs, 100V ÷ 415V, 50/60Hz, 45mA@100V, 30mA@230V, 20mA@415V |
| COMMUNICATION INTERFACE |
| PC (Windows), Tablet/Smartphone(iOS, Android) |
USB (PC only) / WiFi |
| MECHANICAL FEATURES |
| Dimensions (L x W x H) |
245 x 210 x 110mm |
| Weight |
1.5kg |
| WORKING ENVIRONMENTAL CONDITIONS |
| Reference temperature |
23°C ± 5°C |
| Working temperature |
0° ÷ 40°C |
| Allowed relative humidity |
<80%HR |
| Storage temperature |
-10 ÷ 60°C |
| Storage humidity |
<80%HR |
| POWER/ENERGY MEASUREMENTS REFERENCE GUIDELINES |
| Features of voltage supplied by public utilities |
EN50160 (only voltage and THDV%) |
| GENERAL REFERENCE GUIDELINES |
| Safety of measuring instruments |
IEC/EN61010-1 |
| Insulation |
double insulation |
| Pollution degree |
2 |
| Encapsulation |
IP65 (case board closed) |
| Measurement category |
CAT IV 300VAC to ground, max 460V between Inputs |
| Max height of use |
2000m |
| Normative |
EMC 2004/108/CE Directive, LVD 2006/95/CE Directive, EN50160, IEC/EN 61010-1, CE MARK, EMC: IEC/EN61326 |