FULLTEST 3 is the Most Advanced Solution for a Complete Compliance with the ActuaL Guidelines
FULLTEST3 is designed to satisfy the requirements of the IEC/EN60204-1:2006 guideline (electrical equipment of industrial machines) and for the new series of prescriptions relative to the IEC/EN61439-1 guideline (Switchgear panels). This last guideline require, among other tests, the Dielectric tests with a test voltage up to 5100V!
|
The innovative FULLTEST3 model was designed for safety electrical test verifies on machines, switchboards in complete compliance with IEC/EN60204-1:2006 and IEC/EN61439-1 guidelines. For this aim the instrument performs a really high number of test which place it as flexible solution also to satisfy all or partially tests of other guidelines (e.g. routine test of IEC/EN60335-1 guideline). Besides continuity of protection conductor, insulation and withstanding tests the FULLTEST3 can perform RCDs test on A, AC, B General, Selective and Delayed devices, Line/Loop impedance measurements also with high resolution (with IMP57 optional accessory), global earth resistance without RCDs tripping and leakage current with external transducer clamp. Other possible test performed are the breakdown current, tripping time current, I2t test relative to MCB with curve B, C, D, K and Fuse type gG and aM. The instrument have actually interfaces as TFT display with touch screen, three USB ports for connection to PC, keyboard, printers, barcode readers and pen drive. A Bluetooth connection is also available for connection to remote devices.
|
COLOUR TOUCH-SCREEN DISPLAY
Besides belonging to a new concept instrument, designed for complies most standards’ requirements, FULLTEST3 is featured by modern solutions such as touch screen display, various parameter settings and management of measurement results. This powerful performance made complex measurements extremely intuitive such as test on MCBs as well as power coordination to avoid thermal effects due to short circuit (test I 2 t).
|
|
INNOVATIVE MEASUREMENT FUNCTIONS
Withstanding test with voltage programmable up to 5100V comply with requirements of IEC/EN61439-1 guideline.
Verify of protection against indirect contacts comply with requirements of IEC/EN60204-1:2006 guideline:
- Continuity of protection circuit (test current from 200mA to 25A)
- Test on RCD protection devices (type AC, A, B) up to 1A
- Earth resistance measurement
- Verify of magnetothermal (MCB curve B, C, D, K) and Fuses (gG, aM) protection coordination
Insulation resistance up to 1000VDC
Residual voltage verify on capacitive elements
Leakage current measurement on the test socket and by transducer clamp (optional accessory ht96U)
Routine test on the socket (power, current)
Phase sequence indication.
|
|