| Sidekick Plus Test Set |
| Dimensions |
279 x 121 x 76 mm (11 x 4.75 x 3 in); 305 x 140 x 114 mm (12 x 5.5 x 4.5 in) (in soft case) |
| Weight |
1.4 kg (3 lb) (includes Li-ion battery pack, soft case, and test leads) |
| Weight (1155-5012 and 1155-5013) |
1.8 kg (4 lb) (includes Li-ion battery pack, soft case, and test leads) |
| Batteries |
Greenlee rechargeable battery pack (Li-ion 3-cell) or 6 AA alkaline batteries |
| Measurements |
| Volts AC |
| Range |
0 to 250 volts |
| Resolution |
0 to 9.99 V = 0.01 V; 10 to 250 V = 0.1 V |
| Accuracy |
±3% |
| Frequency response |
40 Hz to 70 Hz |
| Volts DC |
| Range |
0 to 300 volts |
| Resolution |
0 to 9.99 V = 0.01 V; 10 to 300 V = 0.1 V |
| Accuracy |
±3% |
| Stress Test |
| Range |
0 to 82 dBrnC |
| Resolution |
0.1 dBrnC |
| Accuracy |
±5 dBrnC overall; ±2 dBrnC from 10 to 50 dBrnC |
| Longitudinal excitation |
+90 dBrnC; ±6 dBrnC |
| Longitudinal Balance |
| Range |
+100 dB to +20 dB |
| Resolution |
0.1 dB |
| Accuracy |
±2 dB from +20 dB to +90 dB, ± 5 dB from +90 dB to +100 dB |
| Longitudinal excitation |
+90 dBrnc (0 dBm), ± 2 dB |
| Leakage |
| Range |
0 to 999 MΩ |
| Resolution |
1 kΩ to 1 MΩ
10 kΩ from 1 MΩ to 10 MΩ
100 kΩ from 10 MΩ to 100 MΩ
1 MΩ from 100 MΩ to 999 MΩ |
| Accuracy |
±5% up to 100 MΩ; ±10% from 100 MΩ to 999 MΩ |
| Resistance |
| Range |
0 to 100 MΩ, autoranging |
| 0 to 99 Ω |
| Resolution |
0.1 Ω |
| Accuracy |
±3% or 1 Ω |
| 100 Ω to 100 MΩ |
| Resolution |
4 digits |
| Accuracy |
±3% |
| Distance to Open (Meter) |
| Range |
0 to 30 km (0 to 100,000 ft) |
| 0 to 30 m (0 to 99 ft) |
| Resolution |
0.3 m (1 foot) |
| Accuracy |
5%/0.6 m (5%/2 ft) |
| 30 to 6095 m (100 to 19,999 ft) |
| Resolution |
4 digits |
| Accuracy |
4% |
| 6096+ m (20,000+ ft) |
| Resolution |
4 digits |
| Accuracy |
10% |
| Loop Current |
| Range |
0 to 110 mA |
| Resolution |
0 to 9.99 mA = 0.01 mA; 10 to 100 mA = 0.1 mA; >100 mA = 1 mA |
| Accuracy |
±2 mA |
| Load Coils |
| Locates |
up to 5 load coils |
| Circuit Noise |
| Range |
0 to 90 dBrnC |
| Resolution |
0.1 dBrnC |
| Accuracy |
±2 dBrnC |
| Power Influence |
| Range |
30 to 110 dBrnC |
| Resolution |
0.1 dBrnC |
| Accuracy |
±2 dBrnC |
| Circuit Loss |
| Range |
+3 to -70 dB |
| Resolution |
0.1 dB |
| Accuracy |
±0.5 dB |
| RFL |
| Distance measurement accuracy |
±0.5% of full scale, ±1 digit |
| Maximum fault resistance |
2 MΩ |
| Fault check/ohms range |
0 to 19.99 MΩ |
| Distance range |
0 to 61 km (0 to 199,999 ft) |
| Fault current |
73 uA and 730 uA depending on fault |
| K-TEST |
| Distance measurement accuracy |
0.5% of DTS, ±0.5 Ω |
| Maximum fault resistance |
20 MΩ |
| Distance range |
0 to 20 km (0 to 65 kft) |
| Fault1 / Fault2 |
> 2 |
| LoopR * 100 |
< Fault1 + Fault2 |
| Tone |
| Tracing tone generator (metallic and common mode) |
500 to 3500 Hz |
| Reference tone |
+14 to -20 dBm; 200 Hz to 20 kHz |
| TDR |
| Range |
10 km (33 kft) |
| Ground Resistance Test |
| Method |
Fall of Potential |
| Measurement range |
0 to 250 Ω |
| Impulse Noise (optional) |
| Filters |
C (700 Hz to 3000 Hz)
E (1 kHz to 50 kHz)
F (5 kHz to 245 kHz)
G (20 kHz to 1100 kHz)
V (to 30 MHz) for VDSL-1 and VDSL-2 circuits |
| Number of available thresholds |
3 |
| Threshold settings |
-65 dBm to +5 dBm |
| Blank time |
10 ms, 125 ms, 1000 ms |
| Termination |
100 Ω, 135 Ω, 120 Ω |
| Measurement time |
1 minute to 24 hours |
| Standards |
ANSI/IEEE 743 |
| Environmental |
| Operating temperature |
-18 °C to 50 °C (0 °F to 120 °F) |
| Storage temperature |
-18 °C to 50 °C (0 °F to 120 °F) |
| Operating humidity |
BS EN 61010 “normal conditions”. Up to 80% to 31 °C decreasing to 50% at 40 °C. Condensation is not permitted. |
| Environmental protection |
This product is protected to BS EN 60529 level IP20CW; do not use in wet conditions (rain or high humidity). |