Sidekick Plus Test Set |
Dimensions |
279 x 121 x 76 mm (11 x 4.75 x 3 in); 305 x 140 x 114 mm (12 x 5.5 x 4.5 in) (in soft case) |
Weight |
1.4 kg (3 lb) (includes Li-ion battery pack, soft case, and test leads) |
Weight (1155-5012 and 1155-5013) |
1.8 kg (4 lb) (includes Li-ion battery pack, soft case, and test leads) |
Batteries |
Greenlee rechargeable battery pack (Li-ion 3-cell) or 6 AA alkaline batteries |
Measurements |
Volts AC |
Range |
0 to 250 volts |
Resolution |
0 to 9.99 V = 0.01 V; 10 to 250 V = 0.1 V |
Accuracy |
±3% |
Frequency response |
40 Hz to 70 Hz |
Volts DC |
Range |
0 to 300 volts |
Resolution |
0 to 9.99 V = 0.01 V; 10 to 300 V = 0.1 V |
Accuracy |
±3% |
Stress Test |
Range |
0 to 82 dBrnC |
Resolution |
0.1 dBrnC |
Accuracy |
±5 dBrnC overall; ±2 dBrnC from 10 to 50 dBrnC |
Longitudinal excitation |
+90 dBrnC; ±6 dBrnC |
Longitudinal Balance |
Range |
+100 dB to +20 dB |
Resolution |
0.1 dB |
Accuracy |
±2 dB from +20 dB to +90 dB, ± 5 dB from +90 dB to +100 dB |
Longitudinal excitation |
+90 dBrnc (0 dBm), ± 2 dB |
Leakage |
Range |
0 to 999 MΩ |
Resolution |
1 kΩ to 1 MΩ
10 kΩ from 1 MΩ to 10 MΩ
100 kΩ from 10 MΩ to 100 MΩ
1 MΩ from 100 MΩ to 999 MΩ |
Accuracy |
±5% up to 100 MΩ; ±10% from 100 MΩ to 999 MΩ |
Resistance |
Range |
0 to 100 MΩ, autoranging |
0 to 99 Ω |
Resolution |
0.1 Ω |
Accuracy |
±3% or 1 Ω |
100 Ω to 100 MΩ |
Resolution |
4 digits |
Accuracy |
±3% |
Distance to Open (Meter) |
Range |
0 to 30 km (0 to 100,000 ft) |
0 to 30 m (0 to 99 ft) |
Resolution |
0.3 m (1 foot) |
Accuracy |
5%/0.6 m (5%/2 ft) |
30 to 6095 m (100 to 19,999 ft) |
Resolution |
4 digits |
Accuracy |
4% |
6096+ m (20,000+ ft) |
Resolution |
4 digits |
Accuracy |
10% |
Loop Current |
Range |
0 to 110 mA |
Resolution |
0 to 9.99 mA = 0.01 mA; 10 to 100 mA = 0.1 mA; >100 mA = 1 mA |
Accuracy |
±2 mA |
Load Coils |
Locates |
up to 5 load coils |
Circuit Noise |
Range |
0 to 90 dBrnC |
Resolution |
0.1 dBrnC |
Accuracy |
±2 dBrnC |
Power Influence |
Range |
30 to 110 dBrnC |
Resolution |
0.1 dBrnC |
Accuracy |
±2 dBrnC |
Circuit Loss |
Range |
+3 to -70 dB |
Resolution |
0.1 dB |
Accuracy |
±0.5 dB |
RFL |
Distance measurement accuracy |
±0.5% of full scale, ±1 digit |
Maximum fault resistance |
2 MΩ |
Fault check/ohms range |
0 to 19.99 MΩ |
Distance range |
0 to 61 km (0 to 199,999 ft) |
Fault current |
73 uA and 730 uA depending on fault |
K-TEST |
Distance measurement accuracy |
0.5% of DTS, ±0.5 Ω |
Maximum fault resistance |
20 MΩ |
Distance range |
0 to 20 km (0 to 65 kft) |
Fault1 / Fault2 |
> 2 |
LoopR * 100 |
< Fault1 + Fault2 |
Tone |
Tracing tone generator (metallic and common mode) |
500 to 3500 Hz |
Reference tone |
+14 to -20 dBm; 200 Hz to 20 kHz |
TDR |
Range |
10 km (33 kft) |
Ground Resistance Test |
Method |
Fall of Potential |
Measurement range |
0 to 250 Ω |
Impulse Noise (optional) |
Filters |
C (700 Hz to 3000 Hz)
E (1 kHz to 50 kHz)
F (5 kHz to 245 kHz)
G (20 kHz to 1100 kHz)
V (to 30 MHz) for VDSL-1 and VDSL-2 circuits |
Number of available thresholds |
3 |
Threshold settings |
-65 dBm to +5 dBm |
Blank time |
10 ms, 125 ms, 1000 ms |
Termination |
100 Ω, 135 Ω, 120 Ω |
Measurement time |
1 minute to 24 hours |
Standards |
ANSI/IEEE 743 |
Environmental |
Operating temperature |
-18 °C to 50 °C (0 °F to 120 °F) |
Storage temperature |
-18 °C to 50 °C (0 °F to 120 °F) |
Operating humidity |
BS EN 61010 “normal conditions”. Up to 80% to 31 °C decreasing to 50% at 40 °C. Condensation is not permitted. |
Environmental protection |
This product is protected to BS EN 60529 level IP20CW; do not use in wet conditions (rain or high humidity). |