Specifications of GL100-WL, GL100-N |
Item |
Description |
Number of channel |
Up to 4 channels
(varies by the type of input module used, and measurement type is fixed with each input module.) |
Interface to PC |
USB 2.0, Wireless LAN (IEEE802.11b) in GL100-WL |
Functions |
Real-time data capturing
Display the captured data value to the LCD in real-time and save the monitoring values
Set conditions using the Menu setting |
While using Wireless LAN:
Output captured data in real-time
Output the saved data from the internal memory
Full control of the GL100 from the PC application software
Send warnings via the e-mail in GL100-WL ( *¹ ) |
While using USB port:
Output captured data in real-time
Output the saved data from the internal memory
Full control of the GL100 from the PC application software |
Display |
LCD (backlit monochrome, graphical type) |
Storage device |
• Built-in RAM (Approx. 4.9 MB)
micro SD memory card
Maximum file size for captured data is 1.9 GB. |
Sampling interval |
0.5 to 30 seconds and 1 to 60 minutes |
Output signal |
Alarm (1 channel), Warnings message is sent via the e-mail in GL100-WL ( *¹ ) |
Power source |
Battery (AA x 2)
USB bus-power (micro USB connector)
* The required power capacity is 5V, 1A when AC adapter for microUSB drive
is used. AC adapter is not included. |
Operating environment |
Temperature: -10 ºC to 50 ºC
Humidity: up to 80% RH (non condensed)
Water resistance: IP54 |
External dimension |
Approx. 66 x 100 x 27 mm (exclude protrusion) |
Weight |
GL100-N: Approx. 125 g, GL100-WL: Approx. 130 g |
Item |
Description |
Supported OS |
Windows: 8.1 / 8 / 7 / Vista (32- or 64-bit), Android OS: 4.3 or later, iOS: 7 or later |
Controlled units |
Up to 10 units |
Item |
Model number |
Description |
Thermistor sensor (Normal type) |
GS-103AT-4P |
Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range: -40 to 105 ºC |
Thermistor sensor (Ultrathin type) |
GS-103JT-4P |
Sensor for GS-4TSR module, 3 m, 4 pcs/set, Temp. range: -40 to 120 ºC |
AC Current sensor |
GS-AC50A |
For GS-DAP-AC module, Cable 200 mm, Current range : 50 A AC |
AC Current sensor |
GS-AC100A |
For GS-DAP-AC module, Cable 200 mm, Current range : 100 A AC |
AC Current sensor |
GS-AC200A |
For GS-DAP-AC module, Cable 200 mm, Current range : 200 A AC |
Dual port adapter |
GS-DPA |
Connect up to two (2) sensors |
Module Extension Cable |
GS-EXC |
Extension cable for input module, 1.5 m long |
Specifications of input module |
Type of measurement |
Temperature, and Humidity
Accumulated temp. (calculated value), Dew-point temp. (calculated value) |
Measuring range |
Temperature: -20 to 85 ºC
Humidity: 0 to 100 % RH |
Type of measurement |
Acceleration in 3-axis (X-, Y-, Z-axis), and Temperature |
Measuring range |
Acceleration: ±2 (20 m/s²), ±5 (50 m/s²), ±10G (100 m/s²)
Temperature: -10 to 50 ºC |
Sampling interval |
5 to 100 ms in memory mode, 0.5 s to 60 min. in direct mode ( *² ) |
Type of measurement |
Illuminance, and UV intensity
Accumulated Illuminance (calculated value), Accumulated UV intensity (calculated value) |
Measuring range |
Illuminance: 0 to 200 klx
UV intensity: 0 to 30 mW/cm² |
Type of measurement |
Carbon dioxide concentration |
Measuring range |
0 to 9999 ppm |
Operating environment |
Temperature: 0 ºC to 50 ºC, Humidity: up to 80% RH (non condensed) |
Type of measurement |
Current
Power (calculated value), Electric energy (calculated value) |
Application circuit |
Single-phase two-wire, Single-phase three-wire system, or Three-phase three-wire |
Sensor |
Clamp-on current probe (optional), Two (2) sensors are able to connect |
Measuring range |
50, 100, 200 A RMS (varies by the sensor) |
Number of channel |
Analog voltage 4 channels,
Logic or Pulse 4 channels ( *³ ) |